Bryant CAPVP series Installation Instructions Download Page 2

2

Table 1 – CAPVP Cased Coil Information

MODEL

SIZE (TON)

FLUSH FIT TO

FURNACE WIDTH

COIL CONNECTION TUBE SIZE (IN.)

Liquid

Suction

CAPVP1917ALA

1.5

17---1/2” / 445 mm

3/8

3/4

CAPVP2517ALA

2.0

17---1/2” / 445 mm

3/8

3/4

CAPVP3717ALA

3.0

17---1/2” / 445 mm

3/8

3/4

CAPVP3721ALA

3.0

21” / 533 mm

3/8

7/8

CAPVP4321ALA

3.5

21” / 533 mm

3/8

7/8

CAPVP6124ALA

5.0

24---1/2” / 622 mm

3/8

7/8

INTRODUCTION

Use this instruction manual to install CAPVP indoor coil on
multipoise furnaces. (See Fig. 1.) The CAPVP coil is enclosed in a

casing.

Downflow

Furnace

Installation

Upflow

Furnace

Installation

Return

Supply

Return

Supply

Evaporator

Coil

A13060

Fig. 1 -- Typical Installation Upflow/Downflow Cased Coils

*  CAUTION: DO NOT MOUNT COIL LOWER THAN

    3˝ (76mm) MINIMUM OR FURN

ACE FAILURE MAY RESULT

Wide Coil

Narrow Coil

Narrow Furnace

Wide Furnace

Field Fabricated

Adapter(s)

3˝ (76mm)

A13061

Fig. 2 -- Adapter(s) Installation When Coil Overhangs or Un-

derhangs Furnace

INSTALLATION

Inspect Equipment

File claim with shipper if equipment is damaged or incomplete.

Select Installation

Upflow CAPVP Coil Installation.

The cased coil is designed to fit furnaces of the same width.

1. Set coil in place on upflow furnace discharge air opening.
2. Ensure coil is level for proper condensate drainage. Do not

tip coil toward condensate drain. Coil casing need not be

fastened or screwed to furnace.

3. When installing wider coil on narrow furnace, create field

fabricated adapter. (See Fig. 2.)

4. When installing narrow coil on wide furnace, create field

fabricated adapter. (See Fig. 2.)

NOTE

: On upflow installations where the indoor coil is placed in

an unconditioned space, a 6” (152 mm) wide piece of insulation
should be applied and wrapped around the outside of coil casing
and supply duct contact point.
See Table 1 for dimensions. Note instructions for placement of coil
casing on furnace.

Downflow CAPVP Coil Installation.

IMPORTANT

: Installing “A” coils rotated 90

_

from the front of

the furnace in downflow applications can cause water blow off or
coil freeze up. This is due to the concentration of air on one coil
slab or lack of air on the opposite coil slab. If the airflow is high
due to ductwork or other causes, and there is a chance for water
blow off, it is recommended that a 3” (76 mm) field--supplied
adapter be placed between the coil and the furnace to allow the air
to distribute evenly to both coil slabs. (See Fig. 3.)

3” (76mm)

A13062

Fig. 3 -- Downflow Installation With Coil Rotated 90

_

1. Set cased coil on supply duct opening.
2. Place field fabricated 3” (76 mm) adapter on coil casing.

Adapter should be tapered to fit coil/furnace combination
when one of them is larger than the other.

3. Set furnace on adapter.

NOTE

:

In downflow installation with a 4--way multipoise

furnace, break off perforated duct flanges on furnace. See furnace
installation instructions.

CONNECT REFRIGERANT PIPING

Use accessory tubing package or field--supplied tubing of

refrigerant grade, see Product Data information for ordering.
Suction tube must be insulated. Do not use damaged, dirty, or

contaminated tubing because it may plug refrigerant flow--control
device. ALWAYS evacuate the coil and field--supplied tubing

before opening outdoor unit service valves.

CA

P

VP

Summary of Contents for CAPVP series

Page 1: ...njury Understand the signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NO...

Page 2: ...abricated adapter See Fig 2 NOTE On upflow installations where the indoor coil is placed in an unconditioned space a 6 152 mm wide piece of insulation should be applied and wrapped around the outside of coil casing and supply duct contact point See Table 1 for dimensions Note instructions for placement of coil casing on furnace Downflow CAPVP Coil Installation IMPORTANT Installing A coils rotated ...

Page 3: ...t sinking material such as a wet cloth CAUTION PERSONAL INJURY HAZARD Failure to follow this warning could result in personal injury Wear eye protection Coil is factory charged with 15 psi nitrogen The coil is under pressure and TXV screen is in place behind liquid line plug DO NOT removed liquid line plug first always remove the suction line plug first to depressurize the coil WARNING REFRIGERANT...

Page 4: ... water damage will occur To further protect against water damage install a float switch to shut the unit off if the water in the secondary pan gets too high NOTE To avoid drainage problems test the primary drain line by slowly pouring water into the pan Check piping for leaks and proper condensate drainage Using the secondary drain as explained in the previous note provides further protection agai...

Reviews: