Bryant BUILDER’S MODEL THERMOSTAT User Manual Download Page 4

 

—4—

 

PRODUCT DATA INFORMATION

 

PHYSICAL CHARACTERISTICS

 

Builder’s/Standard Programmable Models:

Dimensions: See drawing
Appearance: Plastic, designer white, textured, white rubber push buttons

Non-Programmable/Programmable Models:

 

Dimensions: See drawing
Appearance: Plastic, eggshell color, textured

 

ELECTRICAL CHARACTERISTICS

 

Builder’s/Standard Programmable Models:

Input Volts/Amps: 24vac, 1 VA

Non-Programmable/Programmable Models:

Input Volts/Amps: 24vac, 5 VA

 

ENVIRONMENTAL REQUIREMENTS:

 

Operating Temperature/Relative Humidity: 32°F (0°C) to 104°F (40°C), 95% rh non-condensing

Storage Temperature/Relative Humidity: –40°F (–40°C) to 134°F (56°C), 95% rh non-condensing

 

PROGRAM SPECIFICATIONS:

 

Builder’s/Standard Programmable Models:

Temperature set point range: 50°F (10°C) to 90°F (32°C)
Manual changeover
Non-volatile memory
Fahrenheit or Celsius selectable
Power-stealing option on AC model
Selectable fan ON or OFF with auxiliary heating (HP model)
Five-minute compressor timeguard
Four cycles per hour maximum
Auxiliary heat LED on heat pump models

Non-Programmable Models:

Temperature set point range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool set points
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Equipment On indicator

Programmable Models:

Temperature set point range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool set points
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Programming days: 7 day
Programming periods: 4—Wake, Day, Eve, Sleep
Hold function
Copy previous day function
Humidity display and control (Thermidistat Control only)
Equipment On indicator (Thermidistat Control only)

 

WIRING REQUIREMENTS:

 

Power: 24vac nominal, 18- to 30-vac, 50/60 Hz

Wiring: Standard thermostat wire 18 to 22 gage.

Summary of Contents for BUILDER’S MODEL THERMOSTAT

Page 1: ...CD with clock NON PROGRAMMABLE THERMOSTATS CLEAN DESIGN Features soft responsive buttons and an easy to read backlit Liquid Crystal Display LCD ACCURATE RELIABLE TEMPERATURE CONTROL LCD shows current...

Page 2: ...y It controls humidification during heating and dehumidification during cooling AUTOMATIC HUMIDITY ADJUST MENT When used with the outdoor temperature sensor the Thermidistat Control automatically adju...

Page 3: ...Programmable Thermostat and Thermidistat Control 7 3 8 1 3 8 4 3 8 Non Programmable Thermostat 5 13 16 1 3 8 3 1 2 Builder s Model Thermostat 4 1 4 2 3 4 3 4 51 2 3 4 31 2 Standard Programmable Therm...

Page 4: ...olatile memory Fahrenheit or Celsius selectable Power stealing option on AC model Selectable fan ON or OFF with auxiliary heating HP model Five minute compressor timeguard Four cycles per hour maximum...

Page 5: ...ool Manual Changeover F C TSTATBBBHP01 B Thermostat Heat Pump Non Programmable 2 Stage Heat 1 Stage Cool Manual Changeover F C PART NO DESCRIPTION TSTATBBSAC01 Thermostat Air Conditioner 5 2 Day Progr...

Page 6: ...ge 7 day programmable heat cool temperature control for 24 vac heating cooling systems with auto changeover Temperature display can be selected to read F or C The TSTATBBPHP01 B Thermostat provides ve...

Page 7: ...istat Control The TSTATBBPRH01 B Thermidistat Control provides single stage or multiple stage equipment operation 7 day programmable heat cool temperature control for 24 vac systems with auto changeov...

Page 8: ...oom temperature display When heating equipment is ON a HEAT ON icon is displayed above the room temperature display EQUIPMENT ON INDICATORS THERMIDISTAT CONTROL When cooling equipment is ON a COOL ico...