ROUTINE MAINTENANCE

Simple, routine maintenance as described below will enhance
your air conditioning system’s ability to operate economically

and dependably. Always remember the following safety

precautions:

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Disconnect all electrical power to the indoor air handler or

furnace before removing access panels to perform any

maintenance. Disconnect power to both the indoor and

outdoor units (see Fig. 1.)

NOTE:

There may be more than one electrical disconnect

switch.

PERSONAL INJURY AND/OR PRODUCT AND

PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in personal injury or

product and property damage.
Although special care has been taken to minimize sharp edges

in the construction of your unit, be extremely careful when

handling parts or reaching into the unit.

CAUTION

!

Fig. 2 -- Main Electrical Disconnect

INDOOR UNIT (Furnace or Fan Coil)

(

Also refer to the furnace or fan coil Owner’s Manual)

S

Check the Air Filter Monthly

There are no filters on your outdoor unit. However, a dirty air

filter on the indoor unit can cause overheating, automatic system
shutdown, and in extreme cases, component failure.

CHECK THE FILTER(S) MONTHLY AND CLEAN OR

REPLACE AS NEEDED. For details on how to check, clean or

replace your filter(s), refer to your furnace or fan coil owner’s
manual. OR, if you have an electronic air cleaner or a larger,

”boxed” air filter, refer to the owners manual supplied with those
products.

S

Coil Cleaning

Your indoor coil is located in a sealed cabinet on your indoor unit
and will require minimal cleaning with routine filter maintenance.

Longer operating cycles and reduced energy efficiency may

indicate the need for a coil cleaning by your Bryant dealer.

OUTDOOR UNIT

S

Coil Cleaning

The most visible part of the outdoor unit is the large ”coil”

wrapped around the inner components of the air conditioner. If
grass clippings, leaves, shrubbery, and debris are kept away from

the coil, minimal care is needed. If the coil becomes dirty, clean

the coil surface with a vacuum cleaner using a soft brush
attachment. Use an up and down motion being careful not to

bend or damage the delicate, aluminum coil fins. If dirt is deep in
the coil, contact your dealer for service.

S

Base Pan Drainage

Periodically check for and remove debris that has settled around
the base of your outdoor unit. This will ensure proper drainage

of the base pan and eliminate standing water inside the outdoor

unit.

S

Level Installation

Your Bryant dealer will install the outdoor unit in a level position.

If the support base settles or shifts and the unit is no longer level,
be sure to re--level it promptly to assure proper drainage. If you

notice water or ice collecting beneath the unit, arrange for it to be
drained away from the unit.

SEA COAST COIL MAINTENANCE

Coastal locations often require additional maintenance of the
outdoor unit due to highly corrosive airborne ocean salt.

Although your new Bryant system is made of galvanized metal
and is protected by top--grade paint, take the additional

precaution of periodically washing all exposed surfaces and the

outdoor coil approximately every 3 months. Consult your
installing Bryant dealer for proper cleaning intervals and

procedures for your geographic area or ask about a service
contract for regularly scheduled professional cleaning and

inspections.