background image

3

MODEL NUMBER NOMENCLATURE

92

5

S

A

30

040

E

14

A

--

A

S - Single Stage
T - Two Stage
M - Modulating

0 --- 90 AFUE
3 --- 93 AFUE
5 --- 95 AFUE
6 --- 96 AFUE
7 --- 97 AFUE

S - Standard
E - Energy Efficient
V - Variable Speed

14 - 14.2”
17 - 17.5”
21 - 21.0”
24 - 24.5”

91 - Legacy
92 - Preferred
98 - Evolution

Voltage

L - Low NOx

1 - 2

Family/Tier

3

Base Eff.

Htg. Stages

4

5

Major Series

6 - 7

Clg. Cap.

Htg. Cap.

8 - 10

Motor

11

12 - 13

Width

14

Voltage

15

Features

Minor Series

16

Major Series

24 -  800 CFM
30 - 1000 CFM
36 - 1200 CFM
42 - 1400 CFM
48 - 1600 CFM
54 - 1800 CFM
60 - 2000 CFM
66 - 2200 CFM
(@ 0.5” ESP)

040=40,000 BTU 

060=60,000 BTU 
080=80,000 BTU 
100=100,000 BTU 

120=120,000 BTU 

Not all familes have these models.

A11165

FURNACE COMPONENTS

RATING PLATE NOT SHOWN

(LOCATED ON BLOWER DOOR)

GAS VALVE

MAIN LIMIT SWITCH

(BEHIND GAS VALVE)

REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.

ELECTRICAL JUNCTION

BOX (IF REQUIRED, 

LOCATION MAY VARY)

MEDIA CABINET

OPERATING INSTRUCTIONS

NOT SHOWN (LOCATED ON

MAIN FURNACE DOOR, SEE 

OPERATING INSTRUCTIONS 

INSIDE DOOR FIGURE).

FURNACE

CONTROL

BOARD

MANUAL RESET

ROLLOUT SWITCH

FLAME

SENSOR

MANUAL RESET

ROLLOUT SWITCH

GAS BURNER

HOT SURFACE

IGNITER

INDUCER MOTOR

ASSEMBLY

BLOWER AND

MOTOR

CAPACITOR/

POWER CHOKE

(IF USED)

BLOWER DOOR

SAFETY SWITCH

A11408

Summary of Contents for 925SA Series

Page 1: ...ntinuous fan speed from a compatible thermostat S External Media Filter Cabinet included S 4 way multipoise design for upflow downflow or horizontal installation with unique vent elbow and optional through the cabinet downflow venting capability S Multi tap ECM blower motor single speed inducer motor and single stage gas valve S Self diagnostics S Adjustable blower speed for cooling continuous fan...

Page 2: ...1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR KGAWF1506UFR Electrical Data 030040 042060 048080 048100 066120 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 8 1 9 7 9 7 12 2 12 2 Unit Ampacity Amps 11 0 13 0 13 0 16 1 16 1 Minimum Wire Size AWG 14 14 14 12 12 Maximum Wire Length Minimum Wire Size Feet 33 28 28 35 35 M 10 1 8 5 8 5 10 7 10 ...

Page 3: ... 66 2200 CFM 0 5 ESP 040 40 000 BTU 060 60 000 BTU 080 80 000 BTU 100 100 000 BTU 120 120 000 BTU Not all familes have these models A11165 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY MEDIA CABINET OPERATING INSTRUCTIO...

Page 4: ...mm LP KGAHA5750125 X X X X X Gas Orifice Kit 1 30mm LP KGAHA5750130 X X X X X Indoor Air Quality Bryant Perfect Air Purifier 16x25 406x635mm GAPAAXBB1625 A08 X X X X X Bryant Perfect Air Purifier 20x25 508x635mm GAPAAXBB2025 A08 X X X X X Bryant Perfect Air Purifier Repl Filter 16x25 406x635mm GAPABBCAR1625 A05 X X X X X Bryant Perfect Air Purifier Repl Filter 20x25 508x635mm GAPABBCAR1625 A05 X X...

Page 5: ... 1090 1050 2 Org 1180 1130 1095 1060 1015 975 935 895 850 800 1 Red 1100 1045 1010 970 920 885 845 790 745 690 100000 SIDE BOTTOM 5 Gry 2040 1970 1885 1795 1720 1635 1540 1450 1360 1230 4 Yel 1550 1505 1460 1415 1365 1325 1280 1230 1180 1135 3 Blu 1780 1730 1690 1645 1610 1555 1481 1400 1310 1210 2 Org 1345 1295 1250 1195 1155 1105 1055 1000 955 915 1 Red 1390 1350 1295 1260 1200 1160 1105 1050 10...

Page 6: ...202 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 205 62 5 229 69 8 120 000 NA NA NA 83 25 3 217 66 1 NOTE See notes at end of venting tables See Table 3 for altitudes over 4500 ft 1370 M Not all families have these models Table 2 Deductions from Maximum Equivalent Vent Length Ft M Pipe Diameter in 1 1 2 2 2 1 2 3 4 Mitered 90º Elbow 8 2 4 8 2 4 8 2 4 NA NA NA NA Medium Radius 90º Elbow 5 1 5 5 1 5 5 1 ...

Page 7: ...3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 137 41 8 142 43 3 100 000 NA NA 62 18 9 147 44 8 157 47 9 120 000 NA NA NA 51 15 ...

Page 8: ... 9 1 22 9 19 5 15 5 N A 80000 20 10 Ft 20 70 78 70 60 20 70 175 183 154 20 70 175 215 181 M 6 1 21 3 23 8 21 3 18 3 6 1 21 3 53 3 55 8 46 9 6 1 21 3 53 3 65 5 55 2 0 20 Ft 20 42 41 33 21 20 70 132 111 89 20 70 157 133 107 M 6 1 12 8 12 5 10 1 6 4 6 1 21 3 40 2 33 8 27 1 6 1 21 3 47 9 40 5 32 6 20 30 Ft 20 25 23 14 1 20 70 94 77 57 20 70 113 94 71 M 6 1 7 6 7 0 4 3 0 3 6 1 21 3 28 7 23 5 17 4 6 1 2...

Page 9: ...f heat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT AP...

Page 10: ...sed Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inner...

Page 11: ... 115 V FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND GND FIELD 24 V WIRING FIELD 115 208 230 460 V WIRING FACTORY 24 V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES C...

Page 12: ...gle c For 1600 CFM 22 in 559 mm round or 14 1 2 x 22 1 16 in 368 x 560mm rectangle d For airflow requirements above 1800 CFM see Air Delivery table in Installation Instructions literature for specific use of single side inlets The use of both side inlets a combina tion of 1 side and the bottom or the bottom only return air openings may be required for airflow requirements above 1800 CFM at 0 5 in ...

Page 13: ...n accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Draft Inducer Motor Draft inducer motor shall be single speed design Primary Heat Exchangers Primary heat exchangers shall be 3 Pass corrosion resistant aluminized steel of fold and crimp sectional design and applied operatin...

Page 14: ...e or change at any time specifications or designs without notice and without incurring obligations E2011 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 09 11 Replaces NEW Catalog No PDS925SA 01 ...

Reviews: