NOTE:

Read the entire instruction manual before starting the

installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause personal injury or property damage.
Consult a qualified installer, service agency, or your distributor or
branch for information or assistance. The qualified installer or
agency must use factory authorized kits or accessories when
modifying this product. Refer to the individual instructions pack-
aged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves.
Read these instructions thoroughly and follow all warning or
cautions attached to the unit. Consult local building codes and
National Electric Code (NEC) for special requirements.

Recognize safety information. This is the safety-alert symbol

.

When you see this symbol on unit or in instructions and manuals,
be alert to potential for personal injury.

Understand the signal word DANGER, WARNING, or CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions that will result in enhanced installation, reliability, or
operation.

INTRODUCTION

Model 9011KAX Electronic Air Cleaner (EAC) is available in 3
sizes: 012 (300 to 1400 CFM), 016 (500 to 1800 CFM), and 020
(700 to 2000 CFM). (See Fig. 1.)

These plate-type air cleaners are designed for use with residential
and light commercial forced-air heating and/or cooling systems.
They may be installed in the vertical or horizontal section of a
typical return-air duct system. (See Fig. 2.)

These air cleaners are easily field-converted from right- to left-
hand units. Cabinets are designed to support up to 400 pounds
when used in under-the-furnace applications.

A.

Cabinet

The cabinet includes an electrical junction box and power safety
interlock, and houses the air cleaner components. These compo-
nents are:

1. Mechanical pre-filters—Expanded aluminum mesh first-

stage filter that removes lint and large dust particles.

2. Cell assemblies—Cells consisting of combined ionizer

wires and collector plates.

Ionizer part of cell has tungsten wires that receive positive
charge and are mounted between grounded aluminum
channels supported by glazed ceramic insulators.

Collector part of cell consists of alternately charged collec-
tor plates.

The EAC components are listed below and shown in Fig. 3.

1. Power door assembly.

2. Two pre-filters.

3. Cabinet containing 2 air-cleaning cell assemblies.

4. A parts bag including electrical bushing, plug buttons, wire

chase, and airflow label.

B.

Power Door Assembly

The power door assembly consists of:

1. Unit operation light, ON-OFF switch, and door attachment

knob—all installed on door cover.

2. Door base plate contains a solid-state power pack that

converts 120vac to high voltage DC (a 240v Conversion
Kit, KEAVC0101240 is available). All wiring is mounted
internally. A line-voltage disconnect (male plug) and high-
voltage buss bar are mounted on the base plate externally.
Four screws must be removed to expose the power pack and
wiring.

The supply circuit to the power pack, which is wired across the
furnace blower motor, is controlled by an ON-OFF power switch.
With the power switch ON (assuming power door is in place and
blower motor is operating), 120vac

±

10 percent single-phase, 60

Hz power is applied to the power pack (240v conversion kit
transformer converts 240v to 120vac). Output of the power pack
assembly is approximately 7300vdc.

These Installation Instructions consist of the following:

Section I—Locating Unit
Section II—Installation
Section III-Electrical Connections
Section IV-Startup and Adjustments
Section V—Routine Maintenance and Service

Fig. 1—Model 31KAX

A91465

Installation, Start-up
and Service Instruction

ELECTRONIC AIR CLEANER

Cancels:

II 901K-12-3

II 901K-12-4

10-01-94

901KAX

—1—

Summary of Contents for 901KAX

Page 1: ...units Cabinets are designed to support up to 400 pounds when used in under the furnace applications A Cabinet The cabinet includes an electrical junction box and power safety interlock and houses the air cleaner components These compo nents are 1 Mechanical pre filters Expanded aluminum mesh first stage filter that removes lint and large dust particles 2 Cell assemblies Cells consisting of combine...

Page 2: ...4 A91466 8 1 2 7 8 IN ELECTRICAL ENTRANCE FOR DUCT APPLICATION REAR MOUNTING FLANGE A 3 16 7 8 2 1 16 C B 21 REMOVABLE POWER DOOR ELECTRICAL ENTRANCE 5 8 IN DIA FOR FURNACE APPLICATIONS LOGO OPERATION LIGHT KNOB ON OFF SWITCH 1 TABLE 1 COMPONENT INFORMATION MODEL 901KAX012 901KAX016 901KAX020 Air Volume Range 300 1400 500 1800 700 2000 Electrical Data Input to power door 120v single phase 60 Hz 12...

Page 3: ... lower than 40 F can cause ionizer wire failure under certain conditions NOTE The maximum operating temperature of the EAC is 125 F II INSTALLATION NOTE See Fig 4 for suggested installation positions CAUTION Turn off all power to furnace or fan coil before beginning installation Proceed as follows to install EAC 1 Remove and discard existing furnace mechanical filters They are not required when us...

Page 4: ...ONNECTIONS All wiring must comply with applicable local and national codes To determine best power wiring routing refer to Section A for Internal Electrical Connections and Section B for External Elec trical Connections NOTE For general information a line to line wiring diagram is provided See Fig 9 Fig 4 Typical Applications A86134 DOWNFLOW APPLICATION RETURN AIR PLENUM FAN COIL UNIT SUPPLY AIR P...

Page 5: ...s a Single Speed Furnaces EAC is wired in parallel with fan motor See Fig 11 b Multispeed Direct Drive Motor If the EAC is wired to a multispeed direct drive motor it must be isolated by a relay or sail switch Use either air cleaner relay P N P283 1203 or sail switch P N 69105D1 See Fig 12 or 13 c Furnaces with Printed Circuit Boards EAC is wired to furnace terminals EAC 1 and EAC 2 See Fig 14 for...

Page 6: ...th fan motor See Figure 16 The secondary leads of transformer 120v connect to electronic air cleaner for proper opera tion A field supplied accessory relay 240v may also be used in place of the 240v conversion kit See Figure 16 Apply 240v relay coil in parallel with fan motor Connect white common wire from EAC to N O contacts then to neutral at service panel Check for 120v 60hz 1ph and ensure sepa...

Page 7: ... and unit components 5 Unit can be installed with airflow through cabinet in either direction Apply provided airflow decal to cabinet observ ing actual airflow direction See Fig 24 IV STARTUP AND ADJUSTMENTS The electronic components of the unit convert the incoming vac to vdc power supply Unfiltered contaminated air passes through an aluminum mesh pre filter which removes large airborne particles...

Page 8: ...evel produced by an EAC Because normal maintenance cleaning is so simple most home owners will choose to personally perform the necessary operations Clean the unit where dust from air cleaner cells will not soil carpets or floor CAUTION Before removing the electronic cells be sure to de energize the system fan to avoid any possibility of circulating unfiltered air back into the system To gain acce...

Page 9: ...omplete dry cycle although this is not necessary CAUTION The electronic cell will be very hot at the end of the dishwasher s cycle Allow it to cool before handling Hot water may accumulate in the tubes sup porting the collector plates Tip the cells to drain tubes Fig 19 EAC Connection to Multipoise Fixed Capacity Furnace Control Board A94081 HUM HUMIDIFIER TERMINAL 24 VAC 0 5 AMP MAX LED OPERATION...

Page 10: ... children c Before placing cells in washing container pour in detergent Use approximately 3 4 cup per cell if con tainer is about size of cell Add enough very hot water to cover cell s d After detergent has completely dissolved place elec tronic cell s in container e Soak cells for 15 to 20 minutes slosh several times and remove f Rinse cells with fine water spray Fig 21 EAC Connection to 2 Stage ...

Page 11: ...asional arcing will occur Continuous arcing may indicate cleaning is necessary The EAC should operate only when the system blower is running B Isolating Malfunctions Switch on the EAC and energize the blower system If the light does not glow remove the cells and replace the door If the light glows with the cells removed the problem is within the cell or cabinet Proceed to items 1 through 3 However...

Page 12: ...age current on 7300vdc 1 MA The LED light circuit output can be checked with a voltmeter The reading should be 4vac 8 Check power supply a Place screwdriver on ground plate access panel At the same time move shank portion of screwdriver towards high voltage output of power supply If arcing occurs when screwdriver comes within approximately 1 8 in of power supply power supply is operating properly ...

Page 13: ...evenly covered with dirt In the case of the 2 cell units each cell should have an even load ing pattern Install turning vanes of air baffles CAUTION Do not block off any of the entering air side opening to the unit Radio or TV interference Accumulation of foreign particles lodged in ionizer sec tion Remove Unit improperly grounded Provide good ground to power pack Ground line of supply line voltag...

Page 14: ... 1994 BDP Co P O Box 70 Indianapolis IN 46206 Printed in U S A 14 901k124 Catalog No BDP 3390 107 ...