REFRIGERANT CIRCUIT

The refrigerant circuit is difficult to check for leaks without the
proper equipment. If inadequate cooling is suspected, contact your
local dealer for service.

WARNING:

System under pressure. Relieve pressure

and recover all refrigerant before system repair or final
unit disposal to avoid serious injury or death. Use all
service ports and open all flow-control devices, including
solenoid valves.

UNIT PANELS

After performing any maintenance or service on the unit, be sure
all panels are fastened securely in place to prevent rain from
entering unit cabinet and to prevent disruption of the correct unit
airflow pattern.

C.

Regular Dealer Maintenance

In addition to the type of routine maintenance you might be willing
to perform, your unit should be inspected regularly by a properly
trained service technician. An inspection (preferably each year, but
at least every other year) should include the following:

1. Inspection and, if required, cleaning of the outdoor and

indoor coils.

2. Inspection and, if required, cleaning of the indoor coil drain

pan.

3. Inspection and cleaning of blower wheel housing and

motor.

4. Inspection of all supply-air and return-air ducts for leaks,

obstructions, and insulation integrity. Any problems found
should be resolved at this time.

5. Inspection of the unit base to ensure that no cracks, gaps,

etc., exist which may cause a hazardous condition.

6. Inspection of the unit casing for signs of deterioration.

7. Inspection of all electrical wiring and components to assure

proper connection.

8. Inspection for leaks in the refrigerant circuit. Pressure-

check to determine appropriate refrigerant charge.

9. Inspection of compressor oil level by service person to

ensure proper oil level is maintained in the compressor
when it is installed and running.

10. Operational check of the unit to determine working condi-

tions. Repair or adjustment should be made at this time.

Your servicing dealer may offer an economical service contract
that covers seasonal inspections. Ask for further details.

Complete service instructions can be found in the unit Installation,
Start-Up and Service Instructions.

D.

Warranty Certificate

Unit 704B has a limited warranty. Be sure to read the warranty
carefully to determine the coverage for your unit.

E.

Before You Call for Service ...

...check for several easily-solved problems.

If insufficient heating or cooling is suspected:

( ) Check for sufficient airflow. Check the air filter for dirt. Check
for blocked return-air or supply-air grilles. Be sure they are open
and unobstructed. If these checks do not reveal the cause, call your
servicing dealer.

If your unit is not operating at all, check the following list for
easy solutions:

( ) Check to be sure that your thermostat temperature selector is set
below the indoor temperature during the cooling season or above
the indoor temperature during heating season. Be sure the SYS-
TEM switch or MODE control is in the COOL or HEAT position
and not in the OFF position.

( ) If your unit still fails to operate, call your servicing dealer for
troubleshooting and repairs. Specify the model and serial numbers
of your unit. (Record them in this manual in the space provided.)
If the dealer knows exactly which unit you have, he may be able
to offer suggestions over the phone, or save valuable time through
knowledgeable preparation for the service call.

F.

In Case of Trouble

If you perform the steps above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.

Dealer’s Name ______________________________________

Telephone__________________________________________

Unit Model_________________________________________

Unit Serial Number___________________________________

—3—

Reviews: