PROGRAMMING NOTES

• If only one Occupied period is selected in Step 1 on

page 3, Occupied 2 and 3 programming steps are
skipped. Further, if only 2 occupied periods are
selected, Occupied 3 programming steps are skipped.

• Heat and Cool set points for Occupied 1 are the same

for every day of the week. Heat and Cool set points for
Occupied 2 and 3 can be adjusted differently for each
day of the week, if desired.

If the start time is set later in the day than the stop
time

, the program will run from the start time to mid-

night and from midnight to the stop time on the same
day.

For example: 9:00pm start, 8:00am stop, on

Monday. In this example the program will run from
12:00am Monday to 8:00am Monday and again from
9:00pm Monday to 12:00pm Monday.

• The Unoccupied settings take effect at all times when:

(

1

) the program is on

and (2

) the current time is out-

side a preset occupied period. For this reason start
and stop times are not necessary for unoccupied.

• If the

same

start and stop times are programmed in for

an occupied period, then it will run 24 hours.

• If one occupied period starts and stops within another

occupied period, the lower occupied number has prior-
ity.

For example: If Occupied 3 is programmed to be

“on” 24 hours, and Occupied 2 is programmed to run
that day, then Occupied 2 settings will take over from
Occupied 3 between Occupied 2 start and stop times.

Advanced Setup Table

*Not applicable for use with Duct-Free Split Heat Pump systems.

Programmin

g

Occupied and Unoccupied Periods

Advanced Setup

STEP NO.

DESCRIPTION

RANGE

FACTORY

DEFAULT

1

Time of day clock set

24 hour

12:00 Am

2

Day of the week

Su - Sa

Mo

3

Display Blanking

Off / On

On

4

Fan Operation

Auto / On

Auto

5

Heat Pump*

Off / On

Off

6

Deadband or Temperature swing

1 - 6 F

2 F

7

Forced minimum difference heat/
cool

0 - 6 F

2 F

8

Cycles per hour

d, d1, 2 - 6

6

9

Thermoglow™ Backlight

Off / On

On

10

Fahrenheit or Celsius

F / C

F

Adjust the time of day
clock.

Select the day of the week.

Pm

Setup

Setup

S u

:

Press the Mode button.
While holding the Mode button,
press the Override button to
enter the Advanced Setup
screens.

IMPORTANT: Be sure to press and hold both the
Mode and Override buttons for a full 10 seconds.

Select display operation,
Full Display (On), or
Minimal display (Off).

Select fan operation,
Fan On Fan, Auto, or Fan Off

Fan

Fan Off

Fan

Display On

Display Off

Select residential Heat
Pump, On or Off.

On

Off

O

F

F

Setup

Setup

Setup

Adjust the deadband
from 1 to 6 F.

Setup

Adjust the minimum

between

cooling and heating
set points.

(0 to 6 F)

Setup

Select the cycles per
hour limit.
d=cycles per hour
limit defeated.
d1=d + defeat 5 min.
Compressor lockout.

(d, d1, 2 - 6)

Setup

Setup

Setup

(1 to 6 F)

Cool

Heat

unoccupied123

Select the display back-
light always

On

, or

Off

after 8 seconds.

ON

Select thermostat
operation in degrees

F

ahrenheit or

C

elsius.

Press the Mode button. While holding the Mode button, press the Override button
to leave the Setup screens. If no buttons are pressed, the display will leave the
setup screens after 30 seconds.

e

Selecting Yes, then pressing Mode will copy the previous day’s program and
then will ask the same copy question again. If yes is selected each time, this
routine will repeat until Saturday is copied to Sunday. After Saturday is copied to
Sunday, the copy command is unavailable.
If no is selected, as in previous steps flashing prompts for input will appear for
start and stop times for Occupied 1. If more than one occupied period was
selected in Step 1 on page 3, then cool/heat set points, and start/stop times for
additional occupied periods will be prompted.