Remote Control Operation -- Quick Start

NOTE:

When transmitting a command from the remote control to

the unit, be sure to point the control toward the right side of the
unit. the unit will confirm receipt of a command by sounding an
audible beep.

1. Turn the unit on by pushing the

ON/OFF

button.

2. If there is a preference for temperature settings to be dis-

played in

_

F rather than

_

C (default), push the recessed F/C

button once using a paper clip or similar object.

3. Select the desired mode by pushing the mode button.

AUTO

COOL

DRY

HEAT

FAN

NOTE:

Cool only units have no heat mode.

4. Select the temperature set point by pointing the control to-

ward the unit and pressing the increase/decrease temperature

set point buttons until the desired temperature appears on
screen.

5. Select the desired fan speed by pressing the

FAN SPEED

button to select desired fan speed.

NOTE:

If unit is operating in Dry mode, AUTO fan speed will be

displayed.

6. Set the airflow direction. When the unit is turned on, the

louvers default to the cooling or heating position. The user

can adjust louver position by pushing the air direction but-
ton or have continuous louver movement by pushing the

swing button.

Emergency Operation

If the remote control is lost, damaged, or the batteries are

exhausted, the

MANUAL

button can be used to run the unit.

Open the front cover panel and press the

MANUAL

button once

briefly when the system is off.
To stop emergency operation, push the

MANUAL

button

twice

or

operate the remote control.

If the

MANUAL

button is only

pushed once, the system will enter TEST mode and run for 30

minutes.

Manual button

A07364

The set conditions of emergency operation are as follows:

S

Preset set point: 76

_

F (24

_

C)

S

Fan speed: AUTO

S

Discharge air direction: Pre--set position based on operation in

“Cool”or “Heat” mode.

REMOTE CONTROL FUNCTIONS

Pressing the On/Off Button

SET TEMP.

C L O C K

SPEED AUTO 

AUTO 

ON/OFF 

INDICATOR

A08034

When the air conditioner is not in operation, the remote control
will display the last set point, mode and time.

S

Press the On/Off button to start the unit.

-- The unit will start in the last operating mode and set

point. The ON/OFF indicator will appear.

S

Press button On/Off to stop the unit.

-- All indicator lights on the unit will go out, and the remote

control will display the set point, mode and time.

NOTE:

If the On/Off button is pressed too soon after a stop, the

compressor will not start for 3 minutes due to the inherent
protection against frequent compressor cycling. The unit will only
emit an audible beep when the signals are received correctly.

Selecting an Operating Mode

Use the Operating Mode button to select one of the available

modes.

SET TEMP.

C L O C K

SPEED

AUTO 

OPERATING MODE

AUTO COOL  DRY  HEAT  FAN

AUTO

COOL

DRY

HEAT

FAN

A08034 / A07548

Setting the Room Temperature Set Point

Pressing the increase temperature set point

and decrease

buttons will raise or lower the temperature.
The unit will confirm signal receipt with a beep and the value of
the set temperature on the display will change accordingly.
The temperature can be set between 62

_

F (17

_

C) and 88

_

F

(31

_

C).

NOTE:

In Cooling mode, if the temperate selected is higher than

the room temperature, the unit will not start. The same applies for
the Heating mode if the selected temperature is lower than the
room temperature.

Summary of Contents for 538MAC

Page 1: ...model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ___________________________________ Serial ___________________________________ INSTALLATION INFORMATION Date Installed _____________________________ DEALERSHIP ...

Page 2: ...ct WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only using approved tubing and accessories If technical assi...

Page 3: ...OR UNIT OUTDOOR UNIT Remote control bracket 10 10 A07539A Indoor Outdoor Unit 1 2 4 5 6 3 8 7 9 10 11 12 13 14 MODE FAN S PEED TEMP AIR DIRECTION SWING LED SLEEP TURBO CLOCK TIMER CANCEL RESET F C AUTO COOL DRY HEAT FAN SET TE MP CLOCK TIMER ON TIMER OFF SPEED AUTO L OW MED HIGH ON OFF 1 2 4 5 6 3 8 7 9 10 11 12 13 14 MODE BUTTON ON OFF BUTTON FAN SPEED BUTTON AIR DIRECTION BUTTON SWING BUTTON LED...

Page 4: ...s in this manual are for demonstration purposes only The actual shape of your air conditioner may be slightly different but the operation instructions are the same Remote Control Display AUTO COOL DRY HEAT FAN S E T T E MP CLOCK TIMER ON TIMER OFF SP EE D AUTO LOW MED H IGH 1 2 4 5 6 3 8 7 9 A08043 1 TRANSMISSION INDICATOR Illuminates when remote control transmits signals to the indoor unit 2 MODE...

Page 5: ...herwise battery leakage may damage the remote control 3 The average battery life under normal use is about 6 months 4 Replace the batteries when there is no audible beep from the indoor unit or if the Transmission Indicator fails to light Set the Clock Before you start operating the air conditioner set the clock of the remote control as outlined below The clock panel on the remote controller will ...

Page 6: ...tem will enter TEST mode and run for 30 minutes Manual button A07364 The set conditions of emergency operation are as follows S Preset set point 76_F 24_C S Fan speed AUTO S Discharge air direction Pre set position based on operation in Cool or Heat mode REMOTE CONTROL FUNCTIONS Pressing the On Off Button SET TEMP CLOCK SPEED AUTO AUTO ON OFF INDICATOR A08034 When the air conditioner is not in ope...

Page 7: ...43 Timer Function TIMER ON to start the unit and TIMER OFF to stop the unit can be used separately or together Timer ON only SET TEMP CLOCK SPEED AUTO AUTO TIMERON A08037 This function will allow the unit to start automatically at the set time The TIMER ON can be set while the unit is on or off UNIT ON Press the TIMER button once The current time flashes next to the TIMER ON display on screen Pres...

Page 8: ...bo mode button once It can be terminated immediately by pushing the Turbo mode again When the Turbo mode is terminated the unit will go back to the original setting Lock Use this function to lock the settings on the remote control and to prevent the settings being changed SET TEMP CLOCK SPEED AUTO COOL LOCK SYMBOL A08039 To lock and unlock the remote control press the Y and B temp buttons simultan...

Page 9: ...ay result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If necessary a mild liquid detergent can be applied and wip...

Page 10: ...rly A window or door is open The outdoor unit is obstructed The fan speed is too low The operation mode is in Fan instead of Cool Clean the air filter Check the temperature and reset if necessary Close the window or door Remove the obstruction Change the fan speed selection Change the operating mode to Cool or reset the unit Heating is Not Working Properly The filter is blocked with dust Temperatu...