background image

 

6

 

10

 

4. If applicable, turn off water sup-

ply to humidifier.

5. If furnace blower will be neces-

sary for cooling system, remem-
ber to turn electric power back
on when needed for air condi-
tioning.

6. If the furnace is being shut down

because of a malfunction, call
your dealer as soon as possible.

ALWAYS KEEP MAIN OIL
VALVE TURNED OFF IF
BURNER IS SHUT DOWN FOR
AN EXTENDED PERIOD OF
TIME.

 

PERFORMING 
ROUTINE 
MAINTENANCE

 

With proper maintenance and care,
your furnace will operate economi-
cally and dependably. Instructions
for basic maintenance follow. How-
ever, before beginning maintenance,
follow these safety precautions:

 

11

12

 

FILTERING OUT 
TROUBLE

 

Dirty air filters will cause a loss of
airflow in your duct system. When
excessive loss of airflow occurs,
the furnace may cycle on its safety
controls. If this condition is left
unattended, the furnace will even-
tually lock out. It is recommended
that the furnace air filters be
checked every 3 or 4 weeks and
cleaned or replaced as necessary.

The air filters are located in the
blower compartment installed in
an internal filter rack which is pro-
vided as standard equipment with
furnace. (See Fig. 2.) To inspect,
clean, and or replace air filters, fol-
low these steps:

1. Turn off electrical supply to fur-

nace. (See Fig. 11.)

2. Remove blower access door in

rear of furnace. (See Fig. 13.)
Lift door up, then out using han-
dle on blower access door.

 

                                    13

 

3. Remove air filters from furnace.

a. Remove filter resting in filter 

rack at an angle in front of 
blower first. Slide filter back 
to clear filter rack ends then 
lift up and out of filter rack 
and blower compartment. 
(See Fig. 14.)

 

14

 

b. Remove second filter lying 

above blower. Slide filter 
toward rear of furnace and 
out of blower compartment. 
(See Fig. 15.)

 

WARNING

 

ELECTRICAL SHOCK 
HAZARD 
Failure to follow this warning
could result in personal in-
jury or death. 
Turn off all electrical power to
furnace before performing
any maintenance or service
on unit.

!

 

CAUTION

 

CUTS HAZARD 
Failure to follow this caution
may result in minor personal
injury. 
Although special care has
been taken to minimize sharp
edges, be extremely careful
when handling parts or
reaching into the furnace.

!

 

CAUTION

 

UNIT OVERHEAT HAZARD
Failure to follow this caution
may result in damage to the
furnace blower motor, over
heat the heat exchanger and
reduce the efficiency. 
Never operate your furnace
without the air filters in place.

!

2

1

1

2

Summary of Contents for 368RAN

Page 1: ...ier WARNING If the information in this manual is not followed exactly a fire or explosion could result causing property damage personal injury or loss of life Do not use this furnace if any part has b...

Page 2: ...erature differ ence throughout the house The combustion chamber is stainless steel for long life and it heats up quickly resulting in higher energy efficiency With only minimal care your new furnace w...

Page 3: ...num Stainless steel combustion chamber Heat exchanger designed and shaped to effi ciently transfer heat from furnace into the home Supply air plenum Fully insulated internal walls minimize heat loss H...

Page 4: ...ng equipment Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters All other operations must be per formed by trained service person nel Observe safety...

Page 5: ...he main burner does not ignite within 30 sec from the call for heat the control will lock out The red button on top of the con trol must be depressed for 3 sec in order to reset the control The contro...

Page 6: ...vided as standard equipment with furnace See Fig 2 To inspect clean and or replace air filters fol low these steps 1 Turn off electrical supply to fur nace See Fig 11 2 Remove blower access door in r...

Page 7: ...Inspect all vent piping inside struc ture for deterioration and vent termi nations outside the structure for blockage Check oil pipes leading to and inside of your furnace for leaks Inspect and clean...

Page 8: ...trol must be depressed for 3 sec in order to reset the control Check for obstructions around the vent termination If the furnace still fails to operate call your service representative For your conven...