Low initial cost, reliable operating effi ciency
deliver substantial return on investment
Bryan EB Series Boiler Specifi cations
NOMINAL OUTPUT
STEAM
APPROX.
BOILER INPUT
OUTPUT
SHIP WT.
MODEL MBH
(KW)
MBH (KW)*
BHP*
LBS./HR** (KG)
LBS. (KG)
EB-75
3,200 (938)
2,560 (750)
75
2,639 (1,197)
5,810 (2,635)
EB-100
4,200 (1,230)
3,360 (984)
100
3,463 (1,570)
7,110 (3,225)
EB-125
5,250 (1,538)
4,200 (1,230)
125
4,329 (1,963)
8,300 (3,765)
EB-150
6,300 (1,845)
5,040 (1,476)
150
5,195 (2,356)
8,420 (3,819)
EB-175
7,325 (2,146)
5,860 (1,717)
175
6,041 (2,740)
11,175 (5,069)
EB-200
8,500 (2,490)
6,800 (1,992)
200
7,010 (3,179)
11,305 (5,128)
EB-240
10,000 (2,930)
8,000 (2,344)
240
8,247 (3,740)
14,455 (6,557)
NOTES: *
*
Nominal output based on boiler industry standard of 80% of input. Actual combustion effi ciencies will be fuel dependent.
** Lbs. steam per hour from and at 212° F.
L.
Internal water-cooled
fur nace with low heat
release rate.
M.
Steam boilers with
extra large drum with high
steam release area ensure
stable water level and dry
steam.
N.
Pressurized design:
inner fi reside casing con-
structed of heavy gauge
steel, completely seal-
welded, lined with high
temperature insulation
and refractory.
J
F
A
E
C
I
B
D
N
L
K
D
M
Quality Construction Features:
A.
Water side or steam side interior ac cessible
for clean
out and inspection, front and rear
open ings, upper and lower drums.
B.
Large volume water leg down comers pro-
mote rapid internal circulation, temperature
equalization and effi cient heat transfer.
C.
Boiler tube and furnace area access panels:
heavy gauge steel casing with 2
high tem-
perature ceramic fi ber and insulation, bolted
and tightly sealed to boiler frame.
D.
Flame observation port at rear of boiler.
E.
Single side access; combustion chamber, tubes and
burner head are completely accessible from one side
simplifying maintenance and minimizing fl oor space.
F.
Minimum sized fl ue vent.
G.
Control panel: all controls installed with connections
to terminal strip.
H.
Forced draft, fl ame retention head type burner. Effi -
cient combustion of oil or gas, plus quiet operation.
I.
Heavy steel boiler frame, built and stamped in accor-
dance with the appropriate ASME Boiler Code.
J.
Heavy gauge steel boiler jacket with rust-resistant
zinc coating and enamel fi nish, insulated with 1½
fi berglass to ensure exceptionally cool outer surface.
K.
Bryan bent water tubes are flexible, individually
replaceable without welding or rolling. Never more
than two tube configurations.
G
H
• True “fl exible water tube” design
• High quality steam for heat
or process
• Pressurized fi ring for maximum
performance