background image

 
 

T:\LWG_PG1\Lieferanten\CMEC MACHINERY&ELECTRIC_5005\Bedienungsanleitungen\Winkelmesser\5005_MAN_Winkelmesser_141060_EN.docx 

 

Digital Protractor    

Operating instructions         

 

141060 
 

Specification 

Resolution:      

0.005°  

Accuracy:  

 

0.33° 

/ 20’ 

Measuring range:  

360° 

Operating temperature:     0 - 40° 

 

 

Power:   

 

Lithium battery CR2032 / 3.0 V 

Digital output:   

RS232 

 

Features 

Digital LCD display 
Zero position (ZERO) 
PRESET (input preset value) 
Degree display (decimal division, in gradations of 60) 

 
 

Instructions for cleaning:  

 

If necessary, clean the housing with a soft, dry cloth (do not use oil or other 
liquids!). 
 

 
 
 

Safety information  

 

 

 

Use the protractor only at the permissible operating temperature 

 

Protect the protractor against liquids and moisture 

 

Do not drop the protractor on the floor 

 

Protect the protractor against mechanical damage 

 

Unauthorised opening of the digital display will result in loss of the 
warranty 

 

The protractor / battery must be disposed of in compliance with the 
regulations

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
Comments:  
In the following instructions, the meanings are as follows: 
Briefly press 

 press button for less than 2 seconds 

Hold down 

 press button for more than 2 seconds 

 
 
 
 

 
Zero / ON button   

 

 
1. To switch the protractor on, briefly press the ZERO/ON button 
2. To switch the protractor off, hold down the ZERO/ON button 
3. To apply a PRESET value, briefly press the ZERO/ON button 

 more 

detailed description in instructions on SET button 

 

 

Display 

 

Degrees with decimal places are displayed on the top line 
On the bottom line, degrees are displayed in gradations of 60 
(degrees/minutes/seconds) 

 

 
 
 
 

SET button     

 

PRESET - Value - Setting 

 

To enter a PRESET value - hold down the SET button.  All available digits are 
displayed.  
 

 

 
The last digit flashes indicating that the value can be changed. With the 
ZERO/ON button, the desired digit - which is to be changed - can now be 
selected. By briefly pressing the button, the flashing digit moves to the left. 
 
In the flashing digit, the desired value can be changed with the MODE button. 
By briefly pressing the MODE button you can select the digits between 0 and 
9. After this, briefly press the Zero/ON button to select the next digit to be 
changed. After you have made the desired setting, hold down the SET button 
to save the entered value. If required, the entered value can now be accepted 
in the measuring mode in any angular position by briefly pressing the 
ZERO/ON button. 
 
 
 
 

 

MODE button  

 

 
By briefly pressing the MODE button, you can switch between different display 
modes. The active display mode is shown at the top of the display. 
 
360° - 180°x 2 - 90°x 4 
 
 
 
 

Change of counting direction 

The counting direction can be changed by briefly pressing the SET button. The 
measured value increases or decreases depending on the direction of rotation. 

 

 
 
 
 
 
 

Key: 

 

1. Display  
2. Angular position clamp 
3. Battery compartment / interface 
4. Movable ruler 
5. Fixed ruler 
6. ZERO/ON button 
7. SET button 
8. MODE button 
9. Wheel for fine adjustment 
 
 
 

 

Reviews: