Technical data
and start-up
NLG5 charger
68
8.2.7.2
Shut-Down Parameters
WARNING
Overheating!
Fire hazard!
There is a danger of the battery catching fire if the wrong parameters or limit values are entered!
Any adjustment values must be adopted from the connected battery's technical documentation or be
given clearance by the manufacturer!
INFORMATION
Shut-down parameters function as an additional safety installation. The charger is shut down for
safety reasons anyway if one of these parameters is reached or surpassed.
1.
Battery temperature over (°C):
Charger shuts down if the battery exceeds the
given maximum temperature.
2.
Battery voltage over (V):
Charger shuts down if the given maximum battery
voltage is exceeded.
3.
Battery charge more than (Ah):
Charger shuts down if the given capacity is
charged.
(Entry
999
= never shut down)
4.
Charging time longer than (h):
Charger shuts down if the given charging time is
reached.
(Entry
999
= never shut down)