©2004,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-1550 UL 06-18-2004
44
A provision for adjusting speed is one of the unique features of the SRE-1550 Stairway Eleva-
tor. The
Speed Adjustment Potentiometer
is located on the top of the Carriage. Adjust ac-
cording to the following procedure:
1.) Loosen the collet nut on the Speed Control Potentiometer approximately one-half turn.
2.) Turn the Potentiometer completely in the counterclockwise direction. This is the
starting point. Turn the Potentiometer in the clockwise direction, aligning the slotted
shaft with the weight range of the user.
3.) The speed may be adjusted by turning the slotted shaft on the Potentiometer
(clockwise = faster, counterclockwise = slower). With the customer seated on the
unit, perform several test runs to arrive at the most to appropriate speed setting.
4.) When the speed has been set satisfactorily, retighten the collet nut.
5.) Recheck the speed.
SPEED ADJUSTMENT
POTENTIOMETER
COLLET NUT
TURN CLOCKWISE, ALIGNING SLOT-
TED SHAFT WITH WEIGHT RANGE OF
CUSTOMER
TURN POTENTIOMETER
COUNTERCLOCKWISE
THEN
CW = faster
CCW = slower
SPEED ADJUSTMENT
INSTALLATION
Summary of Contents for SRE-1550 Electra-Ride II
Page 13: ...2004 1996 BRUNO INDEPENDENT LIVING AIDS INC 13 SRE 1550UL06 18 2004 INSTALLATION...
Page 14: ...2004 1996BRUNOINDEPENDENTLIVINGAIDS INC SRE 1550 UL 06 18 2004 14 INSTALLATION...
Page 54: ...2004 1996BRUNOINDEPENDENTLIVINGAIDS INC SRE 1550 UL 06 18 2004 54 HARDWARE...
Page 55: ...2004 1996 BRUNO INDEPENDENT LIVING AIDS INC 55 SRE 1550UL06 18 2004 HARDWARE...
Page 56: ...2004 1996BRUNOINDEPENDENTLIVINGAIDS INC SRE 1550 UL 06 18 2004 56 HARDWARE...
Page 57: ...2004 1996 BRUNO INDEPENDENT LIVING AIDS INC 57 SRE 1550UL06 18 2004 HARDWARE...
Page 58: ...2004 1996BRUNOINDEPENDENTLIVINGAIDS INC SRE 1550 UL 06 18 2004 58 WIRING SCHEMATIC RESIDENTIAL...