© 2019 Brunner GmbH
Installation manual (1.4)
9
8
INSTALLATION
The stove has to be installed vertically on a load-carrying floor. Any differences in height can be
compensated using the M10 screws screwed into the floor frame/foot.
The floor under the
IRON DOG
must exist of an incombustible cover. Materials as glass, steal, ceramic tiles
or natural stone can be used. See also the information in the chapter 'Distances'.
The exhaust gas stub of the Iron Dog 01, Iron Dog 02 and Iron Dog 06 can be removed from the rear and
placed on the top. Exhaust gas stub and blanking cover are fixed from within the firing chamber with two
inside hexagonal bolts each. For modification remove the stove top and exchange the position of the exhaust
gas stub and the blanking cover. The baffle plate (not Iron Dog 06) can be removed for a better accessibility.
After modification replace the parts again in their correct position, paying attention to a perfect placing of the
stove rope seals.
The stove top of the IRON DOG 03 is protected by two swiveling retaining plates, so that with loading one
side of the unfolded stove top plates the device does not turn over. The retaining plates are accessible by the
opened firing chamber door.
Before using the stove, please check whether the stove top is protected
Illustr. 2: Lever open
Illustr. 3: Closing the lever
Illustr. 4: Losening the retaining plate
The maximally allowable load of the unfolded stove top
plates of the Iron Dog 03 is about 10 kg. Point this out to the
operator of the Iron Dog 03.