14
ERROR SEARCH
Error search
Possible cause
Background
Solution
Draught not available or not
sufficient.
Outside temperature high-
er than indoor temperature,
or the chimney cover on the
roof is heated by the sun
Control chimney draught
Warming-up fire in the chim-
ney
Wait until outside temperature
is below indoor temperature
Fuel unsuited
Wood logs are to big
Wood is damp or wet
Use dry and smaller wood
Without sufficient combus-
tion air supply bad igniting
and flow
Control push rod position
(Start-up position)
Control combustion air supply
to the installation area
Open fire door a little for a
short time
Combustion air not sufficient
Minimum distance between
ash layer in the ash pan and
bottom grate too small
Empty the ash pan
Fire burns weakly, much smoke, window becomes black
Possible cause
Background
Solution
Fuel unsuited
Wood logs are to big
Wood is damp or wet
Fire chamber temperature
too low
Only dry wood gives high ig-
nition temperature with de-
sired heat emission.
Combustion air not sufficient Without sufficient combus-
tion air supply bad igniting
and flow.
Control the position of the
push rod