BRUEL & KJAER 3639-E Product Data Download Page 3

3

The NMT is controlled remotely by Environmental Noise Management Software Type 7843 (see 

BP 2100

),

ANOMS airport noise monitoring software or Noise Monitoring Software Type 7802 (see 

BP 1573

),

allowing remote setup, data and system status viewing, data download and analysis. An option allows the
user or system integrator to implement control by third party software, through the documented
instruction set included with the relevant configurations.

The NMT is modular both in hardware and software, giving a very flexible solution that matches a wide
range of needs. Software modules are pre-installed on the NMT and licenses can be moved from one NMT
to another, if required, using Environmental Noise Management Software Type 7843. Using this control
software, the NMT can be configured as needs arise, making the system very cost-effective.

Configurations

Standard configurations of the NMT Type 3639 (see Tables and 2) include:
• The support of two different microphones (Outdoor Microphone Type 4952 or Weatherproof Microphone

Type 4184)

• Remote operation by different central control software (Environmental Noise Management Software Type

7843, ANOMS airport noise monitoring software, Noise Monitoring Software Type 7802 or customer-
defined third party software), not included with the NMT. Each software opens up different functionality
in the NMT

*

. For example, Environmental Noise Management Software Type 7843 enables the Type

3639-E-200 series to:
– Continually stream user-defined data to the Environmental Noise Management System’s server or

ANOMS airport noise monitoring software’s server 

– Operate as a broadband terminal with no noise event detection, thus permitting a very cost-effective

NMT both with growth potential and with the possibility for remote licensing for easy reconfiguration
to allow event detection (Type 3639-E Event Analysis Option BZ-7844)

• The support of different communication protocols: RS–232, PSTN and GSM, GPRS, LAN and WLAN,

depending on the NMT configuration and the central control software (not included with the NMT). Some
configurations include the required hardware for communication

Table  1

Overview of the standard configurations of Noise Monitoring Terminal Plus Type 3639-E 

* See also Product Data for Type 7843, Type 7802 and the ANOMS Brochure.

NMT

Microphone

Central Control Software

Communication 

Protocols Supported

(As Standard)

Noise Monitoring Terminal Plus Type 3639-E

4952

Brüel & Kjær NMS

Type 7802

RS–232, PSTN, GSM

Noise Monitoring Terminal Plus Type 3639-E-001 including 
PSTN Modem ZM-0070

4952

Brüel & Kjær NMS

Type 7802

RS–232, PSTN

Noise Monitoring Terminal Plus Type 3639-E-002 including 
GSM Modem ZM-0071

4952

Brüel & Kjær NMS

Type 7802

RS–232, GSM

Noise Monitoring Terminal Plus Type 3639-E-200 for 
ENMS

4952

Brüel & Kjær ENMS
Type 7843, ANOMS

LAN, GPRS

Noise Monitoring Terminal Plus Type 3639-E-203 for 
ENMS, with GPRS Router

4952

Brüel & Kjær ENMS
Type 7843, ANOMS

LAN, GPRS

Noise Monitoring Terminal Plus Type 3639-E-300 for 
System Integrators

4952

Customer-defined 

software

RS–232, PSTN, GSM

Noise Monitoring Terminal Plus Type 3639-E-301 for 
System Integrators, with PSTN Modem

4952

Customer-defined 

software

RS–232, PSTN

Noise Monitoring Terminal Plus Type 3639-E-302 for 
System Integrators with GSM Modem

4952

Customer-defined 

software

RS–232, GSM

Summary of Contents for 3639-E

Page 1: ...ptional Weather data monitoring optional Camera support optional Remote operation via LAN public telephone lines mobile phone or GPRS Modular hardware software for easy on site servicing Noiseeventtri...

Page 2: ...monitoring terminal and its accessories NMT PLUS Type 3639 E or NMT ADVANCED Type 3639 G Includes Wall Pole Mounting Kit UA 1685 Outdoor Microphone 4952 NMT 3639 E Weatherproof Microphone 4184 NMT 36...

Page 3: ...noise monitoring software s server Operate as a broadband terminal with no noise event detection thus permitting a very cost effective NMT both with growth potential and with the possibility for remot...

Page 4: ...el Kj r During transport the microphone can be safely placed inside the NMT cabinet For more information see Product Data BP 2099 NMT Microphone Central Control Software Communication Protocols Suppor...

Page 5: ...n kit is available for continuous operation of the NMT under extreme weather conditions when running with mains power supply The NMT also includes a watchdog function that ensures that in the rare eve...

Page 6: ...wer consumption The NMT complies with IEC 61672 Class 1 specifications and has a dynamic range of 110 dB Broadband Measurements and Frequency Analysis The NMT performs all the broadband analyses neede...

Page 7: ...and liquid precipitation can be monitored Alternatively a two parameter Weather Station MM 0316 for windspeed and direction can be installed The external weather station mounted for example on a mast...

Page 8: ...s are done using Noise Monitoring Software Type 7802 see Product Data BP 1573 The 300 series NMT configurations allow remote control of the NMT by customer defined third party software through the doc...

Page 9: ...39 E Microphone Type 4952 Range 48 3 129 3 dB CORRECTION FILTERS For Microphone Types 4184 and 4952 Type 3639 G 3639 E is able to correct the frequency response to compensate for sound field free fiel...

Page 10: ...nt on the size of the hard disk Standard configuration consists of a 40 GB hard disk giving at least six months storage space 90 days for Type 3639 E G 200 series Retention Time User defined INTERFACE...

Page 11: ...ENMS and ANOMS including GPRS Router Type 3639 G 300 Noise Monitoring Terminal Advanced for System Integrators Type 3639 G 301 Noise Monitoring Terminal Advanced for System Integrators including PSTN...

Page 12: ...hone 45 77 41 20 00 Fax 45 45 80 14 05 www bksv com info bksv com Local representatives and service organisations worldwide BP 2098 _ BP 2098 14 2014 06 Br el Kj r reserves the right to change specifi...

Reviews: