5 of 14
Notch bottom of hole for trim and tilt wiring.
Select proper fasteners and drill bit size.
Determine thickness of mounting surface.
• Less than 0.8 in. (20 mm) thickness: Drill
three (3) 9/32 in. (7 mm) diameter holes to
use 8 mm bolts and nuts and washers pro-
vided.
• 0.8 in. - 1.2 in. (20 - 30mm) thickness: Drill
three (3) 1/8 in. (3 mm) holes to use screws
provided.
Drill three holes at mounting hole locations.
Mounting Control
Position remote control behind mounting
surface. Align mounting plate with remote
control. Install four washers and screws and
tighten screws to 35 in./lbs.(4 N·m).
Align mounting plate with holes and secure to
mounting surface. Use bolts and nuts if surface
thickness is less than 0.8 in. (20mm) thick and
screws for surface thicknesses between 0.8
(20mm) and 1.2 in. (30mm) thick. Tighten screws
or bolts and nuts to 53-71 in./lbs.(6-8 N·m).
IMPORTANT:
Make sure remote control as-
sembly is secure and does not move during op-
eration.
Position lock ring in mounting plate. Orient notch
for neutral lock lever UP as shown.
1. Shaded area
006303
006339
1
006340
006341
1. Notch, lock ring
006374
1
UP