41&$*'*$"5*0/
• The installation must conform with local codes, or in the absences of local codes with the National
Fuel Gas Code, ANSI Z223.1/NFPA54; Internati onal Fuel Gas Code, Natural Gas and Propane
Installation Code, CSA B149.1; or Propane Storage and Handling Code, B149.2, as applicable.
• The LP gas supply cylinder to be used must be:
1- Constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.)
Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for
transportation of Dangerous Goods and Commission, CAN/CSA-B339 as applicable;
2- Provided with a listed overfilling prevention device;
3- Provided with a cylinder connection device compatible with the connection for the appliance.
• Always place the appliance on a firm and level surface.
• Solid fuels shall not be burned in this gas appliance. When using decorative Lava Rocks, use only
Lava Rocks (INCLUDED).
• The appliance shall be used only outdoors in a well-ventilated space and shall not be used in a
building, garage or any other enclosed area.
• When in use, keep the appliance area clear and at least 40 in / 101.6 cm side, back and top
clearance from combustible materials, gasoline and other flammable liquid and vapors. Do not use
the appliance under overhead combustible surfaces. Certain items or materials, when stored under
the appliance or nearby, will be subjected to radiant heat and could be damaged.
1SPEVDUOBNF
6$1'32,17(),5(3,7
',1,1*7$%/(
.PEFM/0
$
3BUFE)FBU0VUQVU
38,000 BTU/HR
'VFM
Propane - LP
(BT4VQQMZ
20 lb. LP - Gas cylinder
.BOJGPME1SFTTVSF
11 Inches W.C.
0SJGJDF4J[FEJBNFUFS
1.9mm
(BT4VQQMZ1SFTTVSF
Max. 250 PSI Min. 25 PSI
4/20
IMPROTANT SAFETY INFORMATION AND PRECAUTION
Summary of Contents for 81054663