1. INSTALLATION MUST BE MADE AND MAINTAINED IN STRICT ACCORDANCE WITH NATIONAL/
LOCAL PLUMBING AND NATIONAL/LOCAL ELECTRICAL CODES (CSA IN CANADA). INSTALLA-
TION MUST BE MADE BY A QUALIFIED ELECTRICIAN. THE IMPROPER ELECTRICAL INSTALLA-
TION AND MAINTENANCE MAY RESULT IN SERIOUS INJURY OR DEATH FOR PERSONNEL OR
LIVESTOCK.
2. EACH ELECTRICAL UNIT MUST BE WIRED THROUGH A FUSED SWITCH BOX AND FUSED AC-
CORDING TO AMPS REQUIRED FOR EACH SPECIFIED ELECTRIC UNIT. SEE EXHIBIT A. CA-
NADIAN ELECTRICAL CODE - - PART 1 REQUIRES LIVESTOCK WATERERS INSTALLED IN
FEEDLOTS IN OPEN FEEDING AREAS TO BE GROUNDED BY A SEPERATE STRANDED COPPER
GROUNDING CONDUCTOR OF AT LEAST NO. 6 AWG TERMINATING AT A POINT WHERE THE
BRANCH CIRCUIT RECEIVES ITS SUPPLY.
3. THIS UNIT MUST BE GROUNDED TO A COPPER GROUND ROD 5/8” (1.6CM) DIAMETER BURIED
AT LEAST 8 FEET (2.4 METERS) IN UNDISTURBED SOIL. SEE EXHIBIT A.
INSTRUCTIONS
AND REPAIR PARTS LIST
WARRANTY INFORMATION
MC - MH - MJ - MK
SERIES AUTOMATIC
WATERERS
READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION
WARNING
We know that you will be pleased with your decision to purchase a Brower waterer. Please take time to familiarize yourself with this
manual. Included are tips that will make use of your waterer more trouble free and more economical. Red and white Brower waterers
were marketed under the Marlor label for 25 years. Marlor waterers carried a light green and white color scheme. Brower parts will ser-
vice most Marlor waterers. This instruction manual covers the following model numbers: MC32E, MC32N, MK32HE, MK32HN, MJ31HE,
MJ31HN, MC32HE, MC32HN, MH30E, MH30N.
EQUIPMENT FOR POULTRY • LIVESTOCK • PETS
P.O. BOX 2000, HOUGHTON, IOWA 52631, USA
TELEPHONE 319-469-4141 • FAX 319-469-4402
E-mail: [email protected] web: www.browerequip.com
COPYRIGHT © 2018
ALL RIGHTS RESERVED
ISBWATERER
Rev. 1.5
PRINTED IN U.S.A.
!
!