9. CLEANING
34
1. Turn the power switch to “OFF”.
2. Remove the screws and the set screws.
3. Apply grease to each of the holes until the grease overflows slightly.
4. Tighten the screws and the set screws in order to push the grease in.
5. Turn the machine pulley by hand to move the needle bar
up and down several times in order to disperse the
grease.
6. Use a cloth to wipe away any excess grease from around
the screws and set screws and from underneath needle
bar bush D.
7. Carry out the reset procedure given below.
<Resetting the cumulative operating time>
After the grease has been applied, carry out the following procedure to reset the cumulative time between grease
applications.
1. Turn the power switch to “ON”. “GREASEUP” will flash in the main display (1) and the buzzer will sound.
2. Press the RESET key (2). The main display (1) will change to stitch number display mode.
3. Press the FUNC (Function) key (4). “n.134 xxx” will appear in green in the main display (1).
(xxx represents the time between grease applications.)
4. Press the rightmost key (5). The “xxx” will change to “0”.
5. Press and hold the ENTER key (6) for two seconds or more.
The buzzer will make a long beep, and then the main display (1) will change to stitch number display mode. (This
completes the reset procedure.)