5. USING THE OPERATION PANEL (BASIC OPERATIONS)
38
KE-430F, BE-438F
<List of parameters>
Parameter
Setting range and initial value
Display
[For program numbers 1 to 89 (1 to 64 for the
438F)]
The setting cannot be changed.
Pattern
[For program numbers 200 to 999]
“---“, 1 to 89 (1 to 64 for the 438F), additional
recorded pattern numbers.
X-scale
20% - 200%
(Limited by available sewing area.)
(Initial value is 100%.)
* The setting can be displayed in “mm” units by
setting memory switch No. 402 to “ON”.
Y-scale
20% - 200%
(Limited by available sewing area.)
(Initial value is 100%.)
* The setting can be displayed in “mm” units by
setting memory switch No. 402 to “ON”.
Sewing
speed
430F: 200 sti/min to 3200 sti/min
438F: 200 sti/min to 2700 sti/min
Setting units are 100 sti/min.
(Initial value is 2000 sti/min.)
* The setting is displayed in units of 10 sti/min.
For a setting of 2000 sti/min, the display will
be “200”.)
2405B
2407B
Initial value
2406B
Initial value
Initial value
Initial value
2408B