3-16
Confidential
2.3
Error Cause and Remedy
■
BUFFER ERROR
Mistake the Interface settings.
■
CARTRIDGE ERROR
A new one cannot be detected for the operation failure of new toner actuator.
■
DIMM ERROR
The failed DIMM is installed, or the DIMM is not installed correctly.
■
DOWNLOAD FULL
Memory full.
Memo :
• The following troubleshooting sections contain both the actions which end users
should take or check and the ones which service technicians should perform.
Step
Cause
Remedy
1
Main PCB ASSY failure
Replace the main PCB ASSY.
<User Check>
- Install the toner cartridges into the machine properly.
Step
Cause
Remedy
1
Power off or front cover opened
while detecting a new toner
cartridge.
Reset the developing bias voltage and
develop roller counter. (Refer to
"Developer Roller Counter Reset"
2
New toner actuator catching on
some position
Re-assemble the new toner actuator.
3
New toner actuator failure
Replace the new toner actuator.
4
Relay front PCB ASSY failure
Replace the relay front PCB ASSY.
<User Check>
- Install the DIMM correctly.
Step
Cause
Remedy
1
Main PCB ASSY failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Main PCB ASSY failure
Replace the main PCB ASSY.
Summary of Contents for HL 5370DW
Page 12: ...CHAPTER 1 SPECIFICATIONS ...
Page 32: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Page 57: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Page 109: ...Confidential CHAPTER 4 PERIODIC MAINTENANCE ...
Page 145: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Page 153: ...5 6 Confidential Fig 5 3 EM D110 4 places Separation pad ASSY ...
Page 154: ...5 7 Confidential 5 GEAR LAYOUT DRAWING Fig 5 4 ...
Page 213: ...5 66 Confidential 3 Remove the Gear 17 black Fig 5 86 4 Remove the Gear 17 white Fig 5 87 ...
Page 261: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...