5-19
Confidential
8. DISASSEMBLY PROCEDURE
■
Preparation
Prior to proceeding with the disassembly procedure,
(1) Unplug
• the AC cord,
• the USB cable, if connected,
• the LAN cable, if connected.
(2) Remove
• the Paper tray,
• the Toner cartridge and Drum unit,
• the DX unit.
Fig. 5-5
Toner cartridge & Drum unit
Paper tray unit
LAN cable
USB I/F cable
AC cord
DX unit