2-72
Confidential
■
Error code 4001
Number of the black drum unit rotations reaches the upper limit soon.
Error code 4002
Number of the yellow drum unit rotations reaches the upper limit soon.
Error code 4003
Number of the magenta drum unit rotations reaches the upper limit soon.
Error code 4004
Number of the cyan drum unit rotations reaches the upper limit soon.
Error code 4201
Number of the black drum unit rotations has reached the upper limit. (Printing does not stop.)
Error code 4202
Number of the yellow drum unit rotations has reached the upper limit. (Printing does not stop.)
Error code 4203
Number of the magenta drum unit rotations has reached the upper limit. (Printing does not stop.)
Error code 4204
Number of the cyan drum unit rotations has reached the upper limit. (Printing does not stop.)
<User Check>
• Prepare a new drum unit.
■
Error code 4300
Number of pages printed with the belt unit will reach the upper limit soon. (90%)
Error code 4400
Number of pages printed with the belt unit has reached the upper limit. (Printing does not
stop.)
<User Check>
• Prepare a new belt unit.
Step
Cause
Remedy
1
Replace the drum unit with a new
one and reset the drum counter.
If the error display is not cleared,
the main PCB is faulty.
Replace the main PCB.
Step
Cause
Remedy
1
Replace the belt unit with a new
one and reset the belt counter. If
the error display is not cleared,
the main PCB is faulty.
Replace the main PCB.
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...