3-68
Confidential
9.7
Control Panel ASSY
*1 For models with touch panel
(1) Remove three screws "a" from the control panel ASSY.
(2) Slightly pull up the rear end of the control panel ASSY and press the front end to the rear to
separate the ASSY from the upper cover.
Note:
Do not pull the control panel ASSY away from the machine since it is connected to
the machine with harnesses.
(3) Slightly lift up the control panel ASSY, disconnect the panel harness and touch panel
harness
*1
from the main PCB, and release them from their cable guides.
(4) Disconnect the LCD flat cable from the main PCB.
Note:
After disconnecting the flat cable, check that it is not damaged at its end or short-
circuited. When connecting the flat cable, do not insert it at an angle. After insertion, check
again that it is not at an angle.
(5)
Models with touch panel
Release the grounding wire
*1
by removing screw "b"
*1
and
remove it from the cable guides.
MFC with touch panel
Assembling Notes:
• Route the panel harness, touch panel harness
*1
and grounding wire
*1
through cable guides
(circled with a dashed line).
• After mounting the control panel ASSY, check that there is no gap between the front end of
the control panel ASSY and that of the upper cover.
"a"
"b" *
1
Upper cover
Control panel ASSY
Grounding wire *
1
LCD flat cable
Touch panel harness *
1
Panel harness
"a"
"a"
(3_064_MFCJ825DW)
"a": Taptite, cup B M3x10
"b": Taptite, cup S M3x6*
1
Summary of Contents for DCP-J925DW
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 20: ...xvii Confidential ...
Page 21: ...xviii Confidential ...
Page 44: ...1 23 Confidential 1 0 08 inches 2 mm or greater curve may cause jams to occur ...
Page 140: ...3 3 Confidential 2 PACKING ...
Page 281: ...4 28 Confidential ADF Copy Chart C A B D ...
Page 292: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 294: ...5 10 Confidential Scanning Compensation Data List ...
Page 297: ...5 13 Confidential Nozzle Test Pattern ...
Page 300: ...5 16 Confidential Configuration List ...
Page 303: ...5 19 Confidential MFCJ430W J432W MFCJ625DW J825DW Key Entry Order ...
Page 318: ...5 34 Confidential PF EXIT Adjust Check Pattern Paper feed roller ...
Page 319: ...5 35 Confidential EXIT Adjust Check Pattern 1 ...
Page 320: ...5 36 Confidential EXIT Adjust Check Pattern 2 ...
Page 321: ...5 37 Confidential EXIT Adjust Check Pattern 3 ...
Page 322: ...5 38 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 327: ...5 43 Confidential Vertical Alignment Check Pattern ...
Page 331: ...5 47 Confidential Left Right Top and Bottom Margin Check Pattern ...
Page 367: ...6 4 Confidential Power supply PCB 100 V series ...
Page 368: ...6 5 Confidential Power supply PCB 200 V series ...
Page 369: ...6 6 Confidential Wiring diagrams ...