![Brother DCP-9045CDN Service Manual Download Page 361](http://html.mh-extra.com/html/brother/dcp-9045cdn/dcp-9045cdn_service-manual_53339361.webp)
Confidential
5-1
CHAPTER 5 SERVICE FUNCTIONS
1. MAINTENANCE MODE
The maintenance mode is exclusively designed for the checking, settings and adjustments of
the machine by using the buttons on the control panel. You can customize the EEPROM
according to the shipment destination of the machine concerned. In addition, you can perform
operational checks of the LCD, control panel PCB and sensors, perform a print test, display the
log information and error codes, and modify worker switches (WSW).
1.1 How to Enter the Maintenance Mode
Press the
Menu
and
Black Start
buttons. Next press the button four times to make the
machine enter the maintenance mode.
TIP:
This machine can enter the maintenance mode in the same way as conventional models; that
is, by pressing the
Menu
,
*
,
2
,
8
,
6
and
4
buttons in this sequence.
The machine beeps for approx. one second and displays “
” on the
LCD, indicating that it is placed in the initial stage of the maintenance mode, a mode in which
the machine is ready to accept entry from the buttons.
Note:
- To exit from the maintenance mode and switch to standby, press the
9
button twice in the
initial stage of the maintenance mode.
- Pressing the
Stop/Exit
button after entering only one digit restores the machine to the initial
stage of the maintenance mode.
- If an invalid function code is entered, the machine beeps for one second and returns to the
initial stage of the maintenance mode.
1.2 How to Enter the End User-accessible Maintenance Mode
Basically, the maintenance-mode functions listed in the
service personnel only. However, you can allow end users to access some of these under the
guidance of service personnel by phone, for example.
The end user-accessible functions are
shaded
09, 10, 11, 12, 25, 31, 45, 52, 53, 54, 72, 75, 77, 80, 82, 87
Function code 10 accesses the worker switches, each of which has eight selectors. You should
not allow end users to access all of those selectors, but you can allow them to access user-
accessible selectors which are
shaded
in the worker switch tables in
The service personnel should instruct end users to follow the procedure given below.
(1) Press
the
Menu
,
Black Start
,
Menu
, and buttons in this order. The “MAINTENANCE
06” appears on the LCD.
(2) To access any other function code, call up the desired code using the and buttons or
numerical buttons. Then press the
OK
button.
To switch the machine back to the standby state, press the
Stop/Exit
button. When each of the
user-accessible functions is completed, the machine automatically returns to the standby state.
Note:
Although Function code 72 is indicated on the LCD, do not use it.
Summary of Contents for DCP-9045CDN
Page 239: ...Confidential 3 106 11 Remove the LCD from the Backlight module Fig 3 129 LCD Backlight module ...
Page 349: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 365: ...Confidential 5 5 Black and white level data for scanning compensation Fig 5 1 ...
Page 382: ...Confidential 5 22 Cover page sample Fig 5 12 End page sample Fig 5 13 ...
Page 405: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 406: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 407: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 408: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 409: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 410: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 411: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 413: ...Confidential 6 10 Filter PCB Circuit Diagram ...