5-29
Confidential
1.4.17 Operational Check of Fans (Function code 78)
<Function>
This function is to check whether each of fans is operating correctly or not. The following fans
are checked.
<Operating Procedure>
(1) MFC7840W/7840N/7450/7440N/7340/7320
Press in order the 7 and 8 buttons in the initial stage of the maintenance mode. The
indication will appear on the LCD as shown in the figure below.
DCP7045N/7040/7030
Press the
or
button. "MAINTENANCE 78" appears on the LCD, and then press the
OK button.
Fig. 5-12
(2) Press the Start button so that the LCD indication is changed in the order shown in the
figure above. The fan operation is also changed as indicated on the LCD.
(3) Press the Stop/Exit button so that the machine stops checking the fans, beeps for one
second and returns to the initial stage of the maintenance mode.
LCD
Parts Name
Description
F1
Fan motor 60
Evacuate hot air of inside of the machine.