3. INSTALLATION
BAS-300G, BAS-311G, BAS-326G
13
<Power supply motor PCB>
<PMD PCB>
Connector
Connection location on
power supply motor PCB
Cord clamp/cable tie
Machine head memory 7-pin
P3 (HEAD-M)
(4)
Upper shaft motor 3-pin
P4 (UVW)
(5)
Synchronizer 14-pin
P5 (SYNC)
(5), (6)
Connector
Connection location on
PMD PCB
Cable tie
Work clamp pulse motor 4-pin black
P3 (PPM)
(5), (6)
Thread trimmer solenoid 6-pin
P6 (SOL1)
(5), (6)
Tension release solenoid 4-pin
P7 (SOL2)
(5), (6)
Y pulse motor 4-pin blue
P8 (YPM)
(5), (6)
X pulse motor 4-pin white
P10 (XPM)
(5), (6)
(Continued on next page)
<Removing>
Press
the tab.
<Securing>
1843B
NOTE:
Route the X, Y and work clamp pulse motor
harnesses so that they do not touch the
PMD PCB.
*1
:
Be sure to make the ground connection.
(Refer to "3-10. Connecting the ground
wire".)