2-25
Confidential
4.6
Troubleshooting for Other Problems
4.6.1 Machine is not turned ON
4.6.2 Unusual noise is generated from the machine
4.6.3 Data cannot be saved in the USB memory
<User Check>
- Connect the AC cord correctly.
Step
Cause
Remedy
1
Connection failure of the panel PCB
harness
Reconnect the panel PCB harness.
2
Connection failure of the top cover
sensor harness
Reconnect the top cover sensor harness.
3
Top cover sensor failure
Replace the top cover sensor ASSY.
4
Panel PCB failure
Replace the panel PCB ASSY.
5
Power supply PCB failure
Replace the power supply PCB ASSY.
6
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check that the front cover is closed correctly.
Step
Cause
Remedy
1
Possible cause differs depending
on the location. Identify the location
with the problem.
When the location with the problem is
identified, check for any foreign object
around that location.
2
Bent or defective part
Replace the part.
<User Check>
- Check that the USB memory is inserted into the USB terminal correctly.
- Replace the USB memory and try saving data again.
Step
Cause
Remedy
1
Rubber key attachment failure
Reattach the rubber key.
2
Rubber key failure
Replace the rubber key.
3
Panel PCB failure
Replace the panel PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for ADS-2000e
Page 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Page 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 54: ...3 2 Confidential 2 PACKING ...
Page 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Page 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...