INSTALLATION AND OPERATION 

INSTRUCTIONS FOR WOODBURNING: 

 
 

 

    
Tested to EN 13229 
 

 

This appliance must be installed and commissioned by a fully qualified, registered engineer. 

THESE 

APPLIANCES ARE DESIGNED TO BURN WOOD ONLY 

 
A “Declaration of Completion” Certificate must be obtained for the installation and retained by the end user.  
Failure to comply with these requirements may void the warranty. 
 

PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, OPERATING OR SERVICING THIS APPLIANCE. 

 
 

                                ISSUE-09-C 

 

 

 

 

Summary of Contents for INSETO 100

Page 1: ...lly qualified registered engineer THESE APPLIANCES ARE DESIGNED TO BURN WOOD ONLY A Declaration of Completion Certificate must be obtained for the installation and retained by the end user Failure to...

Page 2: ...missions to the atmosphere It is important therefore for appliances to be operated in accordance with our instructions in a manner that maintains a high temperature in the firebox with an adequate sup...

Page 3: ...MAINTAINING THE APPLIANCE 16 A DAILY CARE 16 B CAST IRON 16 C GLASS CLEANING 16 D BROKEN GLASS 16 E ASH REMOVAL 16 F FLUE MAINTENANCE 16 G ROPE SEALS 16 H SOAPSTONE 16 I AIR CONTROLS 17 SPARES 18 CHIM...

Page 4: ...materials used for welding do not contain cadmium in any form Subject Regulation CE no 1935 2004 It is declared that in all our products the materials that are destined to come into contact with foods...

Page 5: ...like an on off switch It is important that the controls are used correctly The air controls are as follows PRIMARY AIR CONTROL SECONDARY AIR CONTROL AIR WASH There is a control for the standard ventil...

Page 6: ...an 20 Coal should never be burnt in these appliances 7 A BURNING WOOD Hardwoods have a far greater calorific value than softwoods weight for weight Any wood needs to be stored in a well ventilated she...

Page 7: ...deposits will block the heat from coming out of the appliance Excess ash in the pan will cause a coal fire to go out and may cause severe damage to the grate It may also prevent the ash door from bein...

Page 8: ...aware of to ensure the efficient and correct operation of your appliance Please read on Take great care choosing the products you use to clean your appliance A major amount of cleaning can be carried...

Page 9: ...revent it from doing what it is designed to Ensure that the ash inside every part of the appliance is removed not just the ash pan Ash will settle on top of the baffle and this is an area that will al...

Page 10: ...t the fire using water 4 Close all windows and doors to the room 5 Call the fire brigade When the chimney has stopped burning have it checked by a specialist for possible cracks or leaks Please review...

Page 11: ...ENTS This appliance has a European sized flue collar that is metric in size An adaptor is required for the initial connection to the flue collar A standard imperial sized adaptor with a crimped leadin...

Page 12: ...arm air to be piped into the room in which the appliance is sited With the installation of the deluxe ventilator kit which comprises of a more powerful fan the warm air can be vented further down the...

Page 13: ...itioning of the appliance and dimensions of the hearth must comply with current national and local building regulations and be at least the minimum sizes shown in the diagram below See FIG 9 If the ap...

Page 14: ...idering the measurements given in the technical specifications you need to account for at least 60 mm of air space above behind and on the two sides of the appliance It is critical that the chamber in...

Page 15: ...e room ADDITIONAL WARM AIR VENTS may be added to the appliance to allow the venting of warm air to a maximum pipe length of 1 5 meters when using the STANDARD ventilator and 4 meters when the DELUXE v...

Page 16: ...2007 2008 Broseley Fires Ltd 16 FIG 12 APPENDIX A TECHNICAL DRAWINGS OF THE APPLIANCES INSERTO 50 INSERTO 80...

Page 17: ...2007 2008 Broseley Fires Ltd 17 INSERTO 100...

Page 18: ...18 APPENDIX B OPTIONAL DELUXE VENTILATION KIT Please allow sufficient clearance below the fan for maintenance INSERTO 80 INSERTO 100 A 300 400 B 25 100 C 190 215 ALL DIMENSIONS IN mm Please refer to...

Page 19: ...on date HETAS ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE CONTACT NUMBER 2ND YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE compl...

Page 20: ...time taken to days from the date of repair whichever is longer Repair or replacement may involve the use of functionally equivalent reconditioned units Replaced parts or components will become the pr...