Telescopic pipe (F) adaptable to the wall thickness.
✓
Anti-mortar cap designed to be used also as template during the installation of the
wall support base.
✓
Regenerative heat exchanger with ceramic core (G) with high thermal efficiency,
equipped with washable anti-dust filters (H).
✓
External grille (I) made of high quality, impact and UV-resistant ABS, colour RAL
9010, with anti-insect net and water drip guard.
✓
Infra-red remote controller with touch technology, LCD display and wall base
supplied as standard. Made from ABS, RAL 9010.
✓
The unit is double insulated: no earth connection is required.
✓
No need of condensation drainage system.
✓
IPX4 degree of protection.
✓
Power supply 220-240V~ 50Hz
2.2 Responsibility of the Installer
✓
Correct Installation, balancing and commissioning of the unit.
✓
Compliance to requirements and local additional rules.
✓
Explanation of the ventilation system to the user.
✓
Warning for the user, to check or replace the air filters on time.
2.3 Responsibility of the Occupant
✓
To ensure maintenance of the ventilation unit on a regular basis. Filters should
be checked, cleaned or replace every 6 months. Details can be found on page
17 (maintenance).
✓
To ensure that the fan is operating. The aircycle ONE+ ventilation units are
designed to operate 24/7.