Alarm Controller - Mains Powered

Product Description

Smoke Alarms are designed to detect smoke par�cles in the 

air.  However,  other  airborne  par�cles,  i.e.  steam,  cooking 

fumes, dust, etc. can also cause smoke alarms to generate 

false alarms. With interconnected smoke/heat alarms, when 

one  alarm  senses  smoke/heat/CO,  all  alarms  will  sound. 

With  these  Brooks  alarm  controllers,  they  can  provide  the 

occupant with easier inspec�on, service and iden�fica�on of 

where these false alarms have ini�ated.
Two models for Alarm Controllers are available:
1.  BAATLS:  To  test,  locate  and  silence  ac�ve  230Vac 

smoke/heat alarms
2. BAAISO: To only isolate ac�ve 230-volt smoke/heat alarms

Compatible Smoke/Heat Alarms

Both  BAAISO  and  BAATLS  can  be  used  with  Brooks  230Vac 

interconnectable  range  of  smoke/heat/CO  alarms,  160e, 

140RC and 3000 Series smoke/heat/CO alarms.
All  160e,  140RC  and  3000  Series  smoke/heat/CO  alarms 

MUST be fi�ed with EIBPLATE when connec�ng to BAATLS or 

BAAISO. The EIBPLATE has an addi�onal terminal to connect 

the  ba�ery  nega�ve  required  for  connec�on  to  BAATLS  or 

BAAISO.
Photoelectric:
Ionisa�on:
Heat:
Smoke/Heat Mul� Sensor:
Heat/CO Mul� Sensor:
Carbon Monoxide:

WARNING:

  Both  BAAISO  &  BAATLS  must  be  installed  by  a 

licensed  electrician  in  accordance  with  regula�ons  for 

electrical  installa�on  (AS3000).  Failure  to  install  the  alarms 

correctly may expose the user to shock or fire hazard.

Due to con�nual product development, Brooks reserve the right to alter product details and specifica�ons without prior no�ce.

BAA

TLS/B

AAISO Da

ta Shee

t R1

BAATLS / BAAISO - Alarm Controllers

Head Office:

 Sydney, 4 Pike Street, Rydalmere 2116 | PO Box 7050 Silverwater BC1811 

Regional Offices:

 Melbourne - Brisbane - Adelaide - Perth - New Zealand 

www.brooks.com.au - Toll Free 1300 783 473

Mains Powered 230V

EIB166e, EIB146RC, EIB3016
EIB161e, EIB141RC
EIB164e, EIB144RC, EIB3014
EIB3024
EIB3028
EIB3018

Summary of Contents for BAATLS

Page 1: ... heat CO alarms All 160e 140RC and 3000 Series smoke heat CO alarms MUST be fi ed with EIBPLATE when connec ng to BAATLS or BAAISO The EIBPLATE has an addi onal terminal to connect the ba ery nega ve required for connec on to BAATLS or BAAISO Photoelectric Ionisa on Heat Smoke Heat Mul Sensor Heat CO Mul Sensor Carbon Monoxide WARNING Both BAAISO BAATLS must be installed by a licensed electrician i...

Page 2: ...o the smoke heat alarms disabling all connected alarms Due to con nual product development Brooks reserve the right to alter product details and specifica ons without prior no ce BAATLS BAAISO Data Sheet R1 BAATLS BAAISO Alarm Controllers Head Office Sydney 4 Pike Street Rydalmere 2116 PO Box 7050 Silverwater BC1811 Regional Offices Melbourne Brisbane Adelaide Perth New Zealand www brooks com au Toll F...

Page 3: ...specifica ons without prior no ce BAATLS BAAISO Data Sheet R1 BAATLS BAAISO Alarm Controllers Head Office Sydney 4 Pike Street Rydalmere 2116 PO Box 7050 Silverwater BC1811 Regional Offices Melbourne Brisbane Adelaide Perth New Zealand www brooks com au Toll Free 1300 783 473 Figure 1 BAATLS Wiring Diagram Block Wiring Diagram ...

Page 4: ...he Alarm Isolator switch can be pressed only when a Smoke Heat Alarm becomes ac ve sounding Block Wiring Diagram Due to con nual product development Brooks reserve the right to alter product details and specifica ons without prior no ce BAATLS BAAISO Data Sheet R1 BAATLS BAAISO Alarm Controllers Head Office Sydney 4 Pike Street Rydalmere 2116 PO Box 7050 Silverwater BC1811 Regional Offices Melbourne Br...

Reviews: