background image

Brooks

®

 1250-55 Series Flowmeters

Installation and Operation Manual

X-VA-1250-55 Series-eng

Part Number: 541B164AAG

May, 2011

Figure 1 Dimensions for Brooks 1250-55 Series Flowmeters

Due to Brooks Instrument’s continuous improvement of our products, all specifications are subject to change without
notice. When ordering parts please include part description, item number (see Figure 2) and type of material required.

If you have any questions regarding installation, maintenance, replacement or use of this flowmeter, please visit our
website at www.BrooksInstrument.com for Customer Service contact information.

 

Figure 2 Parts List for Brooks 1250-55 Series Flowmeters

 

 

 

Number 

Description 

Frame Assembly 

Tube Assembly 

Lens 

Lens End Cap(s) 

Fitting 

Jack Screw O-ring 

Jack  Screw 

Jack Plug 

Jack Plug O-ring 

10 

Top Gasket 

11 

Bottom Gasket 

12 

Retaining Clip 

13 

Optional Valve 

14 

Valve Knob 

15 

Valve O-ring 

16 

Panel Nuts 

SPECIFICATIONS 

ACCURACY: 

± 10% Full Scale – 65 mm 
± 5% Full Scale – 150 mm 

FLOATS: 

Black Glass Ball Float 
Sapphire Ball Float 
Stainless Steel Ball Float 
Tungsten Carbide Float 
Tantalum Float 

FRAME BACKPLATE: 

Anodized Aluminum 

END BLOCKS AND 
ELASTOMERS: 

Aluminum with Buna-N 
Brass with Buna-N 
Stainless Steel with Viton® 
fluoroelastomer 

FITTINGS: 

-27 FNPT Fittings 

GLASS TUBE: 

Precision Formed Borosilicate 

MAXIMUM 
TEMPERATURE: 

200°F (93 °C) 

MAXIMUM 
PRESSURE: 

200 PSI (13.8 Bar) 

Reviews: