![background image](http://html1.mh-extra.com/html/bronpi/bristol/bristol_installation-operating-and-servicing-instructions_2818479029.webp)
28
SECONDARY MENU PARAMETERS
CODE
MIN
DEFAULT
MAX
SAFETY Temperature Activation
TSI
80º
100º
140º
SAFETY FAN Temperature Activation
TSA
100º
135º
180º
SAFETY Function Enable
SIC
0 [off]
1 [on]
1 [on]
SAFETY FAN Function Enable
SAF
0 [off]
1 [on]
1 [on]
STANDBY Function Enable
Stb
0 [off]
1 [on]
1 [on]
BUZZER Function Enable
Enb
0 [off]
1 [on]
1 [on]
Fan Speed P01
U01
00
16
100%
Fan Speed P09
U09
00
70
100%
Fan Speed P10
U10
00
100
100%
Temperature Range of Regulation for Proportional Modality
DEL
20º
20º
100º
•
P01 / P09 / P10 Speed REGULATION (parameters U01 / U09 / U10)
-
Enter in SECONDARY Menu
-
Select the parameter to verify/modify : the fan works automatically at the set speed
-
Modify the value until the desired value : in this way it is possible to control the speed directly.
-
Memorize by pushing button
P4
-
Eventually repeat the operation for the other speeds/parameters
-
To exit, wait about 10 seconds.
Supply:
230 Vac ±10%~ 50HZ: EMI filter on side
Protection:
Internal Fuse
Temperature Probe:
Working Temperature: -50°C / 250 °C
Range of Measure: 0 – 180 °C: ± 1°C
Output:
FAN: 230 Vac Imax: 0,8A/1,5A high power version
Dimensions:
Inbox Controller 120 x 80 x 50 [mm]
Applied Rules:
EN 60730-1 50081-1 EN 60730-1 A1 50081-2
2.2
SPECIFICATIONS ACCORDING TO THE MODEL
2.2.1
MODEL VOLGA
Travel
You can move the insert in three different ways:
-
With a forklift, leaving it over its platform.
-
With a wheelbarrow: swing it from the rear and drop it over its platform.
-
Screw the handles to the side of the chamber and introduce a bar through
the holes.
Placement of the handles for the transport
Inside of the combustion chamber you can find two handles to make easier the
movement of the equipment.
To attach the handle you must unscrew the screws on the side of the chamber,
place the handle and screw them again (
see drawing D19
).
NOTE:
To make lighter the insert move away the baffle plate and all the other pieces inside the de combustion chamber. To move it, raise slightly the
glass. This will block the unexpected opening of the door.
Admission of fresh air
Due to the high power of this models of inserts it is advisable to foresee an air intake coming from outside the room to avoid the overheating
of the equipment.
Isolation of the insert: advantages and drawbacks
Some thermal insulator can be placed between the facing and the insert.
Every way, all cautions must be taken to avoid an overheating of the walls and every constructional elements nearby the equipment (for
instance, wooden beam), and at the moment of the placement these materials will be insulated according to the rules.
Advantages:
-
A lower loss of heat. This is only valid in case of the insert is beside an outer wall. Unless the case the heat will not be lost, it will be
dissipated in the first step by the facing and the to the adjacent rooms.
D19
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
INSERTS
EN
Summary of Contents for BRISTOL
Page 103: ...102 ...