13
3. OPERATING ELEMENTS
Key
Function
On / off (1)
Switches the unit on and off
Rfs
Cell (2)
Indicates the method of flash release
Speed (3)
For fast charging and flash times. See explanation
in Chapter 8
Lamp key 1 or 2
(5.1, 5.2)
Switches the appropriate lamp circuit on and off
Energy regulation
channel 1 (6)
Changes the flash energy in channel 1.
Press briefly to change by 1 / 10, long press by
1 / 1 f-stops
Energy regulation
channel 2 (7)
Changes the flash energy in channel 2.
Press briefly to change by 1 / 10, long press by
1 / 1 f-stops
Output control (8)
The flash energy of both channels is changed
together
Modelling light on / off (9)
Switches the modelling light of both channels on
and off. The info display tells you the duration
until the modelling light switches off automatically
to save power (example: mod10s > modelling light
is on for 10 seconds)
Eco operation (10)
When "eco" is activated, the charging time is twice
as long. At the same time the number of flashes
per battery charge increases
Sync (11)
Permits the selection of different methods of release:
1 x press > release by photocell
2 x press > release by RFS 2
3 x press > release by photocell and / or RFS 2
Selection key (14)
Use the key to scroll between the various menu
functions
Menu and acknowledge-
ment key (15)
Use the key to go from the info display to the
menu, and to confirm your selection in the menu
There is an explanation of menu navigation in
Chapter 7
Test (16)
A test is initiated and the blue "ready" display
appears (as soon as the charge / discharge operation
has been completed)
Sync socket (18) /
Mini USB (19)
For release via the sync cable, or software update
via Mini USB (only possible in Service Centre)