Page
7
B101075-1-0807
Arrange with your local gas company or licensed con-
tractor to have a gas supply line connected to the inlet
of the stainless steel flex tube assembly. The gas supply
must have a shutoff valve inside the wall and must be
shutoff when the grill is not in use.
Use pipe thread sealant or Teflon tape at the threads
of each connection being careful to not allow any of
these materials into the flare seat. Test for gas leaks
as directed by the grill’s Owners Manual.
The grill and its individual shutoff valves must be dis-
connected from the gas supply piping system during
any pressure testing of that system at test pressures
in excess of 1/2 PSIG.The grill must be isolated from
the gas supply piping system by closing its individual
manual shutoff valves during any pressure testing of
the gas supply piping system at test pressures equal
to or less than 1/2 PSIG.
WARNING: D
O
NOT
SUPPLY
LP
GAS
TO
A
GRILL
DESIGNED
FOR
NATURAL
GAS
OR
NATURAL
GAS
TO
A
GRILL
DESIGNED
FOR
LP
GAS
.
Gas leak tests should be completed as directed in the
grill owner's manual.
Fasten the four 1/4-20 x 1 3/4" eyebolts (4) to the top
of the square post using 1/4 - 20 x 3/4" bolts, 9/32 ID
x 5/8 OD flat washers, 1/4 lock washers, and 1/4-20
hex nuts.
Position the grill head onto the eyebolts and fasten with
1/4 lock washers and 1/4-20 Hex nuts.
F
IGURE
3.
P
ATIO
B
ASE
A
SSEMBLY
4
Figure 3
5