Broce K00037 Installation Manual Download Page 3

Pressurized Cab Filter

K00037

15. You’re now going to mount the filter back 

onto the broom the same way you took it off. 

It is ideally a job for 2 people but with time, 

one person can get it attached.

16. Once attached, you’ll need to connect the 

hosing back together and the wiring.

17. For the wiring, the triangle end should fit 

back into where you removed it from. Then 

take the modified end and come over behind 

the horn and unplug the white wire. Also  

remove the nut on the black wire which is 

where you will ground it to.

18. Now plug the red wire into where the 

white one was. Then put the white one back 

one. Next take the black wire and put it in the 

ground spot and reattach the screw.

19. After everything is attached, it’s a good 

idea to take any loose wires and zip tie them 

up so that they are out of the way. Best place 

is to tuck it in between the filter and the hose.

20. Lastly, install a 25 amp fuse into position 

#9 in the fuse box which is located in the cab.

13

14

17

You can see a video of this install on 

the Broce website or by visiting our 

YouTube channel.