126
Brocade FastIron X Series Chassis Hardware Installation Guide
53-1001723-02
Replacing an interface module
6
It is important to wait a minimum of 10 seconds between the removal and insertion of a line
module. Re-insertion of a line module less than 10 seconds after the removal of a line module
may result in the line module not being properly recognized.
Removing an interface module
To remove an interface module, first perform the steps in section
on page 125, then complete the following steps.
1. Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector
located in the lower right corner of the chassis front.
2. Use the #2 Phillips-head or flathead screwdriver to loosen the two screws on the ends of the
module.
3. Pull the card ejectors towards you, and away from the module front panel. This action unseats
the module from the backplane.
4. Pull the module out of the chassis, and place in an anti-static bag for storage if desired.
5. If you plan to replace the removed module with a
different type
of module, you must first
remove the module configuration. To do so, enter the no module <slotnum> command at the
global CONFIG level of the CLI, then save the configuration to flash memory. For example,
FastIron(config)# no module 4
FastIron(config)# exit
FastIron# write mem
NOTE
If you attempt to insert a module of a different type without first removing the previous module
configuration, the system will display an error message.
6. Install a new module in the slot. For information about performing this task, refer to
CAUTION
If you do not install a module in a slot, you must keep the slot panel in place. If you run the
chassis with an uncovered slot, the system will overheat.
Installing a new interface module
You can install an interface module in the FSX,
FSX 800
and
FSX 1600
chassis while the chassis is
powered on and running.
NOTE
The interface modules are interchangeable among all FastIron X Series chassis devices. However,
if you try to install them in a Brocade chassis other than a FastIron X Series, the chassis and
interface modules will not function properly.