Brocade FastIron GS and FastIron GS-STK Hardware Installation Guide
79
53-1001783-01
Power supply specifications
6
DRAFT: BROCADE CONFIDENTIAL
Input connector and plug
lists the input connectors for the power supplies.
shows the power plug and connector for AC power supplies.
FIGURE 51
AC Power Cable Plug and Input Connector
FGS624-STK power drawn from outlet with 1 power supply
with 2 CX4+1XFP
121 W
FGS648-STK power drawn from outlet with 1 power supply
with 2 CX4
170 W
FGS624-STK power drawn from outlet with 2 power supplies (PS
efficiency goes down as load increases)
with 2CX4+1XFP
161 W
FGS648-STK power drawn from outlet with 2 power supplies (PS
efficiency goes down as load decreases)
with 2 CX4
204 W
TABLE 22
Input Connector for Power Supplies
Power Supply
Input Connector Properties
RPS-FGS
Standard IEC type (IEC 320)
C14 type: UL/CSA 15A/250V, VDE 10A/250V
Orientation: Ground pin down
RPSDC-FGS
2-position Phoenix Contact
The power supply is connected to Earth Ground using wire attached to the ground
stud on the power supply rear panel.
TABLE 21
Maximum Power Supply Consumption for FGS-STK Models (Continued)
Model
Maximum Power
Consumption
2