TABLE 17
Environmental status and maintenance commands (continued)
Command
Information displayed
psShow
Status of all operational power supplies
fanShow
Status and RPM of all operational fans
chassisShow
Serial number, time awake, and additional information about each
component
slotShow
Slot occupancy
errShowerrDump
System error log. Refer to the
Brocade Fabric OS Message Reference
for
more information on the messages in this log.
Interpreting POST and boot results
The Brocade DCX performs Power-On Self-Test (POST) by default each time the chassis is powered on, rebooted, or reset. The Brocade
DCX can be rebooted using the
reboot
(to reboot each CP individually) or
fastBoot
commands. The
fastBoot
command reboots the
switches without running POST. If the active CP blade is rebooted, it fails over to the standby CP blade.
POST
The Brocade DCX automatically performs POST each time it is powered on or reset.
To verify that POST has completed without error:
•
Verify that all LEDs return to a normal state after POST completes (
If one or more LEDs do not return to a normal state, and this is not due to the Brocade DCX being set to beacon, refer to the
relevant LED table to identify and correct the problem. For port blades, and CP and core switch blades, the
slotShow
command
can be used to check the status of the slots. For information about turning beaconing on or off, refer to the
Brocade Fabric OS
Administration Guide
.
•
Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact the Brocade DCX supplier for support.
•
Review the system error log using the
errShow
or
errDump
commands.
Any errors detected during POST are written to the system log, which is accessible through the
errShow
command. For
information about error messages, refer to the
Brocade Fabric OS Message Reference
.
POST includes the following steps:
1. Preliminary POST diagnostics are run.
2. Operating system is initialized.
3. Hardware is initialized.
4. Diagnostic tests are run on several functions, including circuitry, port functionality, ability to send and receive frames, all aspects
of memory, parity, statistics counters, and serialization.
Boot
In addition to POST, boot includes the following steps after POST is complete:
1. Universal port configuration is performed.
2. Links are initialized.
Interpreting POST and boot results
Brocade DCX Backbone Hardware Installation Guide
144
53-1000685-24
Summary of Contents for DCX Backbone
Page 8: ...Brocade DCX Backbone Hardware Installation Guide 8 53 1000685 24...
Page 12: ...Brocade DCX Backbone Hardware Installation Guide 12 53 1000685 24...
Page 14: ...Brocade DCX Backbone Hardware Installation Guide 14 53 1000685 24...
Page 24: ...Brocade DCX Backbone Hardware Installation Guide 24 53 1000685 24...
Page 28: ...Brocade DCX Backbone Hardware Installation Guide 28 53 1000685 24...
Page 46: ...Brocade DCX Backbone Hardware Installation Guide 46 53 1000685 24...
Page 50: ...Brocade DCX Backbone Hardware Installation Guide 50 53 1000685 24...
Page 82: ...Brocade DCX Backbone Hardware Installation Guide 82 53 1000685 24...
Page 138: ...Brocade DCX Backbone Hardware Installation Guide 138 53 1000685 24...
Page 142: ...Brocade DCX Backbone Hardware Installation Guide 142 53 1000685 24...
Page 148: ...Brocade DCX Backbone Hardware Installation Guide 148 53 1000685 24...