Installation of the Brocade DCX 8510-8
●
●
●
●
●
●
●
●
Time and items required
You can set up and install the Brocade DCX 8510-8 in the following ways:
• As a standalone unit on a flat surface.
• In a 19-inch Electronic Industries Association (EIA) cabinet, using the 14U Rack Mount Kit (provided).
• In a mid-mount telecommunications (Telco) rack, using the Mid-Mount Rack Kit available from your
Brocade DCX 8510-8 supplier.
This chapter describes how to set up the Brocade DCX 8510-8 as a standalone unit. For rack-mount
installation instructions, refer to the appropriate manual as described in the following table.
The following table describes the main installation and setup tasks, the estimated time required for
each, and the items required to complete the task based on a fully populated Brocade DCX 8510-8 (512
Fibre Channel ports using the FC16-64 port blades). Configurations with fewer ports require less time.
These time estimates assume a prepared installation site and appropriate power and network
connectivity.
Installation tasks, time, and items required
TABLE 2
Installation task
Time estimate
Items required
Site preparation and unpacking
Brocade DCX 8510-8
30 minutes
1/2-in. socket wrench (to remove pallet bolts).
#2 Phillips screwdriver(for cable management comb).
Pallet jack.
Hydraulic lift or assisted lift, able to raise to a minimum of
140 cm (55 in.), with a minimum capacity of 115 kg (254
lb). The Brocade DCX 8510-8 weighs 161.2 kg (355 lb)
with eight FC16-64 port blades installed (512 ports).
Installing rack mount kit
30 minutes
Refer to the
14U Rack Mount Kit Installation Procedure
or
the
Mid-Mount Rack Kit Installation Procedure.
Mounting and securing Brocade
DCX 8510-8 in rack
30 minutes
Brocade DCX 8510-8 Backbone Hardware Reference Manual
23
53-1002180-08
Summary of Contents for DCX 8510-8
Page 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Page 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...