Brocade TurboIron 24X Series Hardware Installation Guide
39
Part Number: 53-1003053-03
Managing the TurboIron 24X
This chapter contains the following sections:
•
•
Managing temperature settings
This section describes how to display temperature settings on the TurboIron 24X and how to change the temperature warning levels.
Using the temperature sensor
The TurboIron 24X comes with two built-in temperature sensors; one at the air intake, and the other at the exhaust (refer to
<Link>Figure 25 on page 51). The temperature sensor at the air intake monitors the incoming air temperature. The temperature sensor at
the air exhaust monitors the air temperature as it exits the device. The temperature sensors cause the device to generate a Syslog
message and SNMP trap if the temperature exceeds a specified warning level The software reads the temperature sensors according to
the device poll time, which is 60 seconds by default. If the temperature equals or exceeds the warning temperature the software generates
a Syslog message and SNMP trap.
You can use the CLI to perform the following:
•
•
“Changing the temperature warning level”
•
“Changing the device temperature polling interval”
Displaying the temperature
By default, the software polls the temperature sensor every 60 seconds to get the current temperature. This poll rate is controlled by the
device poll time, which also controls how often the software polls other system components.
To display the temperature of a device, enter the
show chassis
command at any level of the CLI. The following shows an example output.
TurboIron#
show chassis
Power supply 1 (NA - NA - Regular) present, status ok
Power supply 2 not present
Fan 1 ok, speed (auto): [[1]]<->2<->3
Fan 2 ok, speed (auto): [[1]]<->2<->3
Fan 3 ok, speed (auto): [[1]]<->2<->3
Fan controlled temperature: 0.0 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->30 deg-C
Speed 2: 25<----->40 deg-C
Speed 3: 35<----->90 deg-C (shutdown)
Boot Prom MAC: 00-00-00
TurboIron#