background image

Page

MODEL  qtr100  

5.  Connect electrical wiring.

 

Run 120 VAC house wiring to installation location. Use 

proper UL approved connector to secure house wiring to 

wiring plate. Connect wires as shown in wiring diagrams.

CONNECt WIrING

3.  Attach 

damper/duct 
connector.

 

Snap damper / 

duct connector 

onto housing. 

Make sure con-

nector is flush with 

top of housing and 

damper flap falls 

closed.

4.  Install 4-

inch round 
ductwork.

 

Connect 4-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a 

roof cap or wall 

cap. Tape all 

ductwork con-

nections to make 

them secure and air tight.

INStALL HOUSING & DUCt

1.  Bend 

housing 
tabs.

 

Use a pliers to 

bend housing 

tABS

 out to 90

0

.

2.  Mount 

housing to 
joist.

 

Hold housing 

in place so that 

the housing 

tabs contact the 

bottom of the 

joist. The hous

-

ing mounts with 

four (4) screws 

or nails. Screw or 

nail housing to joist through lowest holes in each mount

-

ing flange,  then through highest holes. NOTE: Mounting 

to 

I-JOISt

 (shown) requires use of 

SPACErS

 (included) 

between the highest hole of each mounting flange and the 

I-joist.

SPACER

(use for mounting to I-Joist)

I-JOIST

TABS

Summary of Contents for VENTILLATION FAN QTR100

Page 1: ...ly lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The impeller should also be replaced OPERATION Use an on off switch or speed control to operate this ventilator See Connect Wiring for details BROAN THREE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such pr...

Page 2: ...rchase separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a built in damper to reduce backdrafts Plan to supply the unit with proper line voltage and appropriate power cable Cooking Equipment Floor COOKING AREA Do not install above or inside this area 45o 45o...

Page 3: ...amper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork con nections to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact the bottom of the joist The hous ing mounts with four 4 screws or nails Screw or nail housing to joist throug...

Page 4: ...Grille Spring 2 req d 14 99111293 Spacer 2 supplied 15 99420665 Thumbscrew 8 18 x 375 INSTALL GRILLE 7 Attach grille to housing Squeeze grille springs and insert them into slots on each side of hous ing 8 Push grille against ceil ing 6 Finish ceiling Install ceiling material Cut out around housing SERVICE NOTE To remove Blower Assembly Unplug motor 7 Remove thumbscrew 15 from motor plate 9 flange ...

Page 5: ...y eficiente como tam bién larga vida y una apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el accesorio del cepillo para sacudir polvo El motor está permanentemente lubricado y nunca necesitará aceite Si los cojinetes del motor están haciendo ruido excesivo o inusual reemplace el motor con el motor de servicio exacto El impulsor también debe ser reemplazado OPER...

Page 6: ...ED Se compran por separado El ventilador funcionará con más eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto más corto posible y un mínimo número de codos Instale una tapa de techo o de pared que tenga un regulador de tiro incorporado a fin de reducir los contratiros Alimente la unidad con el voltaje de línea y el cable eléctrico apro piados Equipo para cocinar ...

Page 7: ...ulador caiga cerrada 4 Instale el conducto redondo de 4 pulgadas Conecte el con ducto redondo de 4 pulgadas al conec tor del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herméticas al aire 2 Monte la cubierta en la vigueta Sostenga la cubi erta en su lugar de manera que las lengüetas de la cub...

Page 8: ...posa n o 8 18 x 0 375 INSTALE LA REJILLA 7 Acople la rejilla a la cubierta Apriete los resortes de la rejilla e insér telos en las ranuras que se encuentran a cada lado de la cubierta 8 Empuje la rejilla contra el cielo raso 6 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta NOTA DE SERVICIO Para desmontar el conjunto del ventilador Desenchufe el motor 7 Sa...

Reviews: