PHASE COUPLER INSTALLATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning de-
vice, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufactur-
er’s guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electri-

cal wiring and other hidden utilities.

6. This unit must be grounded.

1. At the service entrance, shut off all power to the breaker box. In

some homes, this will be the

MAIN

breaker in the

CIRCUIT BREAKER 

PANEL

. If there isn’t a main power shut OFF (master switch) or you

can’t find it do not attempt the work. Call a licensed electrician.

2. Remove the circuit breaker panel cover.

3. Use a circuit tester or AC voltmeter to be sure the circuits are OFF. 

Check to make sure that there is no voltage from the screw termi-
nals of several circuit breakers to the ground or neutral bus bar.

4. The

PHASE COUPLER

will need to be wired directly to two circuit

breakers. It is a violation of the electrical code to use an existing
breaker that already has a wire connected to it. Install a new

220V,

15A, DOUBLE-POLE CIRCUIT BREAKER

. These breakers have a bar

between the paddles so that if one breaker detects any overloaded
condition, both will trip.

 TIP: If you don’t have any space in your panel for new circuit

breakers, use a quad-pole breaker. You will need to remove two ex-
isting breakers that are adjoining each other. The quad breaker will
need to have two of the poles rated for the amperage as the ones
removed. For example, if you removed two 20-amp breakers, you
would need a 20/15/15/20 quad breaker. The two 15-amp poles

will be for the new phase coupler while the two 20-amp
poles will be for the circuits that were connected to the
old breakers. A home improvement or electrical supply
store should have a good assortment of these.

5. Install a single-gang electrical box for the phase cou-

pler near the breaker box. Use either a metal or plastic
outlet box that complies with local electrical ordinanc-
es.

6. Run electrical cable (minimum 75

0

C rated) between

the circuit breaker panel and the outlet box for the
phase coupler. The cable should be secured with a
clamp or wire nail to the wall stud within a few inches
of the mounting box. Use 14/3 cable, which has three
conductors plus a ground wire.

7. Use wire nuts to connect BLACK to BLACK, RED to

RED, GROUND (bare wire) to GROUND (bare wire).
The WHITE wire is not used. Cap-off both ends of the
WHITE wire with a wire nut.

LINE

Black

NEUTRAL

White

GROUND

Bare

Copper

CIRCUIT BREAKER PANEL

120VAC

BLACK

RED

PHASE

COUPLER

GRD

BLACK

RED

GRD

15
15

To

SWITCHES

and

VENTILATORS

WHITE

GROUND BUS BAR

220V, 15A

DOUBLE-POLE

CIRCUIT BREAKER

MAIN

8. At the circuit breaker box, connect the ground wire to the

GROUND 

BUS BAR

. Some panels do not have a separate ground bus bar so

the ground wire must be connected to the neutral bus bar. The
ground wire must be connected for safety purposes.

9. Connect the BLACK wire to one of the 15-Amp circuit breakers.

10. Connect the RED wire to the other 15-Amp breaker.

11. Check to be sure that all the wires are securely fastened, no

copper is exposed (except for the ground wire) and all screws
are tight. You can confirm that the phase coupler is wired to the
correct breakers if you can read 220 to 240 volts AC between
the two breakers when the power is turned on. If there is no
voltage between the two breakers, check to be sure that both of
the breakers and the master breaker are “ON”. If there is still no
voltage between the two breakers, then they are probably on the
same leg, and you will have to select another breaker for one of
the wires.

12. Replace the circuit breaker panel cover.

13. Restore power to the main breaker.

Summary of Contents for SMSK102

Page 1: ...d condition both will trip TIP If you don t have any space in your panel for new circuit breakers use a quad pole breaker You will need to remove two ex isting breakers that are adjoining each other The quad breaker will need to have two of the poles rated for the amperage as the ones removed For example if you removed two 20 amp breakers you would need a 20 15 15 20 quad breaker The two 15 amp po...

Page 2: ...to determine the location of the Master control Only the Master control can place the system in vacation mode disable mode change the system level etc The Master control does all the calculations required to determine how much fan on time is needed to meet a home s ventilation re quirements Ventilation requirements are determined by the system level setting The other controls Slaves will be linked...

Page 3: ...in the Initial Setting of System Level section for help 5 When you have finished setting the System Level press and re lease SET button twice at the Master control to exit Program Mode Master control LED will turn off after exiting Program Mode HOW TO SET VACATION MODE Vacation Mode enables the home s occupants to temporarily disable the Broan SmartSense program When in the Vacation Mode the Master...

Page 4: ...R FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES AND FUSES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to m...

Reviews: