- 5 -
FUSE REPLACEMENT
IF LIGHTS FAIL TO OPERATE,
DISCONNECT POWER AT THE SERVICE
ENTRANCE. CHECK THE FUSE AND
REPLACE IF NECESSARY.
1. Raise or remove the lower decorative flue.
2. Remove the cover from the fuse box.
3. Unscrew the cap from the fuse holder and
remove the fuse.
4. Replace the fuse with the same size and
amperage (5 x 20mm, 4 amp, 125 volt).
Do not use fuses greater than 4 amps.
Fuses greater than 4 amps may
damage the transformer.
5. Reinstall the fuse holder cap, fuse box cover
and flue.
6. Reconnect power at the service entrance.
MAINTENANCE
Proper maintenance of the Range Hood will
assure proper performance of the unit.
Grease Filters
The
grease filters
should be cleaned
frequently. Use a warm detergent solution.
Grease filters are dishwasher safe.
See “INSTALL FILTERS” section for removal
and installation instructions.
Non-Ducted Recirculation Filter
The non-ducted recirculation filter should be
changed every 6 months.
See “INSTALL FILTERS” section for removal
and installation instructions.
NON-DUCTED
RECIRCULATION
FILTER
FUSE
FUSE
BOX
DECORATIVE
FLUE
GREASE FILTERS