2. MEASURE INSTALLATION
Dimensions for the most common installations are shown below.
Adjust your measurements for various heights of ceilings, soffits, cabinets or
cooktops. For proper operation, the hood must be a minimum of 24" and a
maximum of 30" above the cooktop.
18"
(457 mm)
Standard 18"
(457 mm) H
over-cooktop
cabinet
24"
(610 mm)
Cooktop
19"
(483 mm)
Top of wood
mounting strip
Hood
RMP Series
Backsplash
(optional)
Standard
8 ft. (2.44 m)
ceiling
Standard 36"
(914 mm)
H cooktop
HH0028A
3. PREPARE THE INSTALLATION
Remove the installation kit from inside the hood.
Make sure that the following items are included:
-Wood strip
-Installation manual
-Accessories including:
.Filters (Quantity varies depending on range hood width)
.Bag of parts including:
Screws
#
10-2" flat head (4),Screws
#
8-3/4" (8), Nuts
#
10-32 (4)
Wall anchors (2), Washers 3/16" ID X 3/4" OD (2)
1
2
3
4
HR0002
Using a Phillips #2 or a
Robertson #2 screwdriver,
unscrew the hood from the
bottom of crate. Refer to figure
beside to locate all 4 screws.
Discard these screws and
remove hood from wood pallet.
- 6 -
INSTALLATION WITH STANDARD 18’’ HIGH
OVER-COOKTOP CABINET
INSTALLATION WITH 12’’ SOFFIT OR
OPTIONAL SOFFIT CHIMNEY RMN SERIES
Maximum distance
between the hood and
the cooktop
Minimum distance
between the hood and
the cooktop