WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power  from  being  switched  on  accidentally.  When  the  ser-

vice disconnecting means cannot be locked, securely fasten 

a  prominent  warning  device,  such  as  a  tag,  to  the  service 

panel.

3.  Installation  work  and  electrical  wiring  must  be  done  by  a 

qualified  person(s)  in  accordance  with  all  applicable  codes 

and  standards,  including  fire-rated  construction  codes  and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of  gases  through  the  flue  (chimney)  of  fuel  burning  equip

-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori

-

ties.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard

-

ous or explosive materials and vapors.

2.  This product is designed for installation in ceilings up to a 7/12 

pitch. Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further informa

-

tion and requirements.

MODEL QTR100L
FAN / LIGHT / NIGHT LIGHT

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

WARRANTY

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appear

-

ance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the 

motor bearings are making excessive or unusual noises, replace 

the motor with the exact service motor. The impeller should also 

be replaced.

OPERATION

The fan, light, and night light can be operated separately. Use a 

3-function wall control. See “Connect Wiring” for details.

BROAN THREE YEAR LIMITED WARRANTY

Broan warrants to the original consumer purchaser of its products that 

such products will be free from defects in materials or workmanship for 

a period of three years from the date of original purchase. THERE ARE 

NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT 

NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE.

During this three-year period, Broan will, at its option, repair or replace, 

without charge, any product or part which is found to be defective under 

normal use and service.

THIS  WARRANTY  DOES  NOT  EXTEND  TO  FLUORESCENT  LAMP 

STARTERS AND TUBES. This warranty does not cover (a) normal main

-

tenance and service or (b) any products or parts which have been subject 

to misuse, negligence, accident, improper maintenance or repair (other 

than by Broan), faulty installation or installation contrary to recommended 

installation instructions.

The duration of an implied warranty is limited to the three-year period as 

specified for the express warranty. Some states do not allow limitation 

on how long an implied warranty lasts, so the above limitation may not 

apply to you.

BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OP-

TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY 

UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-

DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF 

OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some 

states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state. This warranty supersedes all prior 

warranties.

To qualify for warranty service, you must (a) notify Broan at the address 

or telephone number stated below, (b) give the model number and part 

identification and (c) describe the nature of any defect in the product or 

part. At the time of requesting warranty service, you must present evidence 

of the original purchase date.

Broan-NuTone LLC    Hartford, Wisconsin 

www.broan.com    800-558-1711

Summary of Contents for QTR100L

Page 1: ...e dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The im...

Page 2: ...chase separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a...

Page 3: ...to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact...

Page 4: ...11293 Spacer 2 supplied 16 99420665 Thumbscrew 8 18 x 375 SERVICE NOTE To remove Blower Assembly Unplug motor 7 Remove thumbscrew 16 from motor plate 9 flange Find the single tab on the motor plate lo...

Page 5: ...l con el due o de la casa Para lograr un funcionamiento silencioso y eficiente como tambi n larga vida y una apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el acce...

Page 6: ...A DE PARED Se compran por separado El ventilador funcionar con m s eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto m s corto posible y un m nimo n mero de codos In...

Page 7: ...s de los conductos para fijarlas y hacerlas herm ticas al aire 3 Acople el conectador del regulador de tiro conducto Conecte a presi n el conectador del regu lador de tiro con ducto en la cubierta Ase...

Page 8: ...de servicio se debe especificar el n mero de la pieza no el n mero de la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bom billas Compre una bombilla incandescente m x 100 W Compre un...

Reviews: