Page 1
MODEL QTR070C
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by a
quali
fi
ed person(s) in accordance with all applicable codes
and standards, including
fi
re-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the
fl
ue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
9. When applicable local regulations comprise more restrictive
installation and/or certi
fi
cation requirements, the aforementioned
requirements prevail on those of this document and the installer
agrees to conform to these at his own expenses.
10. When performing installation, servicing or cleaning this unit, it
is recommended to wear safety glasses and gloves.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read speci
fi
cation label on product for further information
and requirements.
MODEL QTR070C
VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
WARRANTY
BROAN-NUTONE CANADA INC.
THREE-YEAR LIMITED WARRANTY
Broan-NuTone Canada warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a period of three
(3) years from the date of original purchase. THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period
, Broan-NuTone Canada will, at its option, repair or
replace, without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS
OR TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS
AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a)
normal maintenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone Canada or an authorized representative), faulty installation or
installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as speci
fi
ed for
the express warranty.
BROAN-NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER’S SOLE AND
EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA
SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the address or
telephone number stated below, (b) give the model number and part identi
fi
cation and
(c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Date of Installation
Builder or Installer
Model Number and Product Description
IF YOU NEED ASSISTANCE OR SERVICE
For the location of your nearest Broan-NuTone Canada Inc. dealer:
Dial Toll Free:
1-888-882-7626
Please be prepared to provide:
Product model number • Date and proof of purchase • The nature of the dif
fi
culty
Broan-NuTone Canada Inc.
1140 Tristar Drive, Mississauga, Ontario L5T 1H9
Installer: Leave this manual with the homeowner.
For quiet and efficient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See “Connect Wiring” for details.
Register your product
online at www.broan.ca