background image

FIG. 4

PRESTIQUE

MEDICINE CABINET

WARNING: Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.

Prepare cabinet.

1. Carefully remove all packing material.

Determine location.

1. The commonly accepted height of bath cabinets is 64" from the finished

floor to the center of the mirror area. However, height may be adjusted
to individual preference.

2. It is recommended that the cabinet be located such that the mounting

screws may be screwed into wall studs to provide maximum strength.

3. Provide 120 VAC power cable through the wall material, directly

behind the light box.

Mount cabinet.

1. Measure and mark four (4) clearance holes in cabinet back at wall stud

locations. Use angle brackets to locate upper holes. (Fig. 1)

2. Drill ¼" dia. clearance holes through cabinet back.
3. Hold angle brackets in place over top set of holes. Mount brackets to

underside of light housing with #6 x ½" screws.

4. Hold cabinet in place and make sure it is level. Screw cabinet to wall

studs.

NOTE: Irregularities in wall surface may cause distortion of cabinet
body when mounted. Place shims between cabinet and wall at appro-
priate corners.

OPTION (If wall studs are not available):
4. Hold cabinet in place and make sure it is level. Mark wall through all four

(4) clearance holes.

5. Set cabinet aside and drill holes in wall material for molly bolts or wall

anchors (not provided).

6. Mount cabinet to wall material.

Connect electrical wiring.

WARNING: Before wiring this product, switch power off at service en-
trance and lock service panel to prevent power from being switched on
accidentally.

1. Remove reflector from wrapper.
2. Remove protective plastic film from reflector and snap light cups onto

sockets.

3. Make electrical connections between house wires and fixture wires on

rear of reflector: black to black, white to white, and greenwire to a per-
manent ground. (FIG. 2)

4. Attach reflector to cabinet.

Mount shelves.

1. Choose the location for the shelves from the five (5) sets of holes lo-

cated on the inside of the cabinet.

2. Insert two (2) shelf tabs into holes, at desired location on one side of the

cabinet. Repeat on the other side, being sure to use holes at the same
height, so the shelf will be level.

3. Set shelves on pins.

Attach mirror doors.

1. Remove wrapping from mirror door. Remove hinge brackets and pres-

sure plates from parts bag.

FIG. 1

FIG. 2

WIRING

ACCESS

HOLE

LIGHT

SOCKET

CUP

MIRROR

DOOR

A99042675C

HINGE

BRACKET

(Pressure plate

beneath

backside)

NYLON

WASHER

BACKSIDE OF

MIRROR DOOR

PRESSURE

PLATE

FIG. 3

HINGE

BRACKET

FIG. 6

FIG. 5

2. Peel paper backing from two (2) pressure plates and affix plates to

backside of mirror door at upper-left and lower-left corners. (FIG. 3)

3. Slide hinge bracket(s) over top of door(s) and lightly tighten screws

against pressure plate(s). (FIG. 3)

4. Place a nylon washer on the pin of the remaining hinge bracket and

insert hinge bracket(s) into hole(s) in bottom of frame.

5. Lift mirror door(s) and insert top hinge bracket(s) into hole(s) in top of

frame. (FIG. 4) Slide bottom of mirror door(s) into lower hinge bracket(s)
(FIG. 5) and lightly tighten screws against pressure plate(s). (FIG 6)

6. Remove the 1" diameter strike plate(s) from the parts bag. Peel off the

paper backing and affix plate(s) to rear of mirror door(s) at the lower
corner(s) opposite the magnetic catch(es).

7. Clear urethane discs are furnished to prevent finger marks on mirror

face. To mount: Remove paper backing and affix to mirror face ½” from
bottom and outside edge.

REFLECTOR

URETHANE DISC

STRIKE

PLATE

MAGNET

SHELF

SHELF

TABS

SCREW

#6 x 3/8”

CLEARANCE

HOLES

SCREW

#6 x ½”

ANGLE

BRACKET

All electrical connections must be made in accordance
with local code ordinances. If you are unfamiliar with
methods of installing electrical wiring, secure the ser-
vices of a qualified electrician.

WHITE TO WHITE

BLACK TO BLACK

GREEN TO

GROUND

WIRE

INSTRUCTIONS FOR
WALL-MOUNT INSTALLATIONS

MODEL NO.

SIZE

FINISH

942224-P1

24”

White

942230-K1

30”

White

942236-K1

36”

White

947224-Q1

24”

Oak

947230-Q1

30”

Oak

947236-Q1

36”

Oak

SCREW

#8 x 1½”

For help, call

us toll free!

1-800-637-1453

Summary of Contents for PRESTIQUE Series

Page 1: ...eflector to cabinet Mount shelves 1 Choose the location for the shelves from the five 5 sets of holes lo cated on the inside of the cabinet 2 Insert two 2 shelf tabs into holes at desired location on one side of the cabinet Repeat on the other side being sure to use holes at the same height so the shelf will be level 3 Set shelves on pins Attach mirror doors 1 Remove wrapping from mirror door Remo...

Page 2: ...als or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THI...

Page 3: ...e las repisas entre los cinco 5 conjuntos de orificios que se localizan en el interior del gabinete 2 Introduzca dos 2 soportes para repisa en los orificios de la ubicación deseada en uno de los lados del gabinete Repita el procedimiento en el otro lado asegurándose de usar los orificios que estén a la misma altura para que la repisa quede nivelada 3 Coloque las repisas sobre sus soportes Colocaci...

Page 4: ...a abertura de la pared 609 mm 24 576 mm x 692 mm x 88 mm 22 11 16 x 27 1 4 x 3 1 2 762 mm 30 728 mm x 692 mm x 88 mm 28 11 16 x 27 1 4 x 3 1 2 914 mm 36 881 mm x 692 mm x 88 mm 34 11 16 x 27 1 4 x 3 1 2 GARANTÍA DE BROAN LIMITADA POR UN AÑO Broan garantiza al comprador original de sus productos que dichos productos estarán libres de defectos en el material y la mano de obra durante un período de u...

Reviews: