Broan NuTone PM44 Manual Download Page 3

3

BLOWER ORIENTATION

IMPORTANT:

 Be sure the blower is correctly orientated. Note ar-

row on the side of the blower housing indicating the correct air flow 

direction (FIGURE 4).

VERTICAL 

DISCHARGE 

VENT 

(TOP OF HOOD)

BLOWER 

DISCHARGE 

– LOCATE AT 

DISCHARGE 

VENT IN TOP 

OF HOOD

THIS 

SURFACE 

TO REAR

FIGURE 4 – VERTICAL DISCHARGE

TO CHANGE LIGHT BULB

Remove lens cover by squeezing the retention tab and rotating the 

lens out. Remove old bulb and replace with a 75-Watt (maximum) 

bulb. Replace lens cover.

CLEANING INFORMATION

FILTER

For greatest efficiency, the aluminum filters should be removed and 

cleaned periodically. To remove the filters, loosen the screw in the 

center of each filter.

To clean, the filter should be soaked in hot water and detergent 

then thoroughly rinsed. The aluminum filter can be cleaned in a 

dishwasher.

EXTERIOR SURFACE

To preserve its lasting beauty, clean with a mild detergent. DO NOT 

use abrasive cleaners.

MOTOR SPEED 
TROUBLESHOOTING

If you have a motor speed problem, please check the following list 

for possible troubles.

.  Blower assembly installed wrong - instended for vertical dis-

charge, but installed for horizontal discharge (FIGURE 4).

2.  Damper flap - not opening.

3.  Reduced airflow because the duct is too small, too long, or has 

too many transitions in the system.

4.  Restriction in the duct (foreign matter, debris).

5.  Undersized or restructive roff or wall cap.

6.  Damper flap in roof or wall cap - not opening.

7.  Wait for 20-30 seconds between speed changes for RPM to 

adjust.

By removing or correcting these adverse factors, the motor speed 

control will be able to decrease from maximum RPM.